Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Titel:Trocar- sharpened needles for image- guided prostate biopsy improve sample quality and performance
Titelzusatz:first clinical results
Mitwirkende:Simpfendörfer, Tobias   i
 Kuru, Timur Hasan   i
 Steinemann, Sarah   i
 Gasch, Claudia   i
 Roth, Wilfried   i
 Hohenfellner, Markus   i
 Hadaschik, Boris   i
Verf.angabe:Tobias Simpfendörfer, Timur H. Kuru, Sarah Steinemann, Claudia Bergsträsser, Svenja Block, Wilfried Roth, Matthias C. Roethke, Markus Hohenfellner and Boris A. Hadaschik
E-Jahr:2014
Jahr:November 3, 2014
Umfang:5 S.
Fussnoten:Gesehen am 11.11.2015
Titel Quelle:In: Journal of endourology
Ort Quelle:Larchmont, NY : Liebert, 1999
Jahr Quelle:2014
Band/Heft Quelle:28(2014), 11, Seite 1384-1388
ISSN Quelle:1557-900X
Abstract:OBJECTIVE: To show the benefit of trocar-sharpened needles for image-guided prostate biopsy compared with standard bevelled needles in patients. MATERIALS AND METHODS: Twenty-four men underwent magnetic resonance imaging-targeted fusion-guided transperineal saturation prostate biopsy, each with half standard bevelled and half trocar-sharpened needles. All taken biopsies were scored (1=worse to 5=best) by one urologist for the following criteria. (1) Accuracy of matching between planned and performed biopsy. (2) Histologic quality of the sample. (3) Elegance, which is the easiness to take the biopsy in proper time, planned position, and best histologic quality. Afterward, the histologic sample quality was evaluated by a blinded pathologist. To show a possible training effect, blinded untrained junior residents performed biopsies in four men (103 cores). RESULTS: Overall, 600 single biopsies were analyzed. The trocar-sharpened needles demonstrated a significantly (p<0.05) better scoring for accuracy and elegance rated by the urologist. The histologic quality scored by the pathologist was superior. Moreover, significantly lower target errors with trocar-sharpened needles were achieved by untrained residents, but not by the experienced user. CONCLUSION: Using trocar-sharpened needles helps urologists to perform targeted prostate biopsy more elegantly and accurately. In addition, the histopathologic sample quality was superior, which may directly improve diagnostic certainty. There is an undeniable training effect in image-guided biopsy and unexperienced users can significantly reduce target errors with trocar-sharpened needles.
DOI:doi:10.1089/end.2014.0121
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag ; Resolving-System: https://doi.org/10.1089/end.2014.0121
 Volltext: http://online.liebertpub.com/doi/pdf/10.1089/end.2014.0121
 DOI: https://doi.org/10.1089/end.2014.0121
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1521632928
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/67900715   QR-Code
zum Seitenanfang