Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Kloth, Jost [VerfasserIn]   i
 Neumann, Regina [VerfasserIn]   i
 Stillfried, Eva von [VerfasserIn]   i
 Stiller, Wolfram [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Ewerbeck, Volker [VerfasserIn]   i
 Weber, Marc-André [VerfasserIn]   i
Titel:Quality-controlled dose-reduction of pelvic X-ray examinations in infants with hip dysplasia
Verf.angabe:Jost Karsten Kloth, Regina Neumann, Eva von Stillfried, Wolfram Stiller, Iris Burkholder, Hans-Ulrich Kauczor, Volker Ewerbeck, Marc-André Weber
Jahr:2016
Umfang:6 S.
Fussnoten:Online veröffentlicht: 23. November 2015 ; Gesehen am 07.04.2017
Titel Quelle:Enthalten in: European journal of radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1990
Jahr Quelle:2016
Band/Heft Quelle:85(2016), 1, Seite 233-238
ISSN Quelle:1872-7727
Abstract:Background: Digital plain radiography (DR) examinations of the pelvis are frequently performed in infants with hip dysplasia. Objective: The purpose was to reduce the radiation dose and to determine objective quality control criteria to ensure accurate assessment. This seems feasible because of higher quantum efficiency of DR and easy assessable anatomical structures for most orthopaedic measurements. Materials and methods: Institutional review board approval was obtained. In this prospective randomized study, 264 patients underwent X-ray examination of the pelvis with standard and reduced dose. The evaluation of the plain-radiographs was conducted using the following criteria: acetabular and center edge angle, closing of the epiphyseal plates and maturation of the femoral head. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more points or more than 2 criteria with 2 points, the radiograph was scored as “not assessable”. The statistical analysis was conducted as non-inferiority-trial. Results: Five (1.9%) examined X-rays were scored as not assessable. There was no statistical inferiority between the examinations with standard (4.57 μSv) or reduced dose (3.06 μSv). Also, the individual evaluation of the defined criteria was dose-independent. Conclusion: The adequate evaluation of hip dysplasia in children and young adults on pelvic radiographs is possible with reduced radiation dose, by simple using an exposure class of 800 instead of 400.
DOI:doi:10.1016/j.ejrad.2015.11.018
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1016/j.ejrad.2015.11.018
 Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X15301601
 DOI: https://doi.org/10.1016/j.ejrad.2015.11.018
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Developmental dysplasia of the hip
 Pelvic X-ray examination
 Plain radiography
 Quality management
 Radiation dose reduction
 Radiation protection
K10plus-PPN:1556422555
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68108055   QR-Code
zum Seitenanfang