Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Völker, Michael [VerfasserIn]   i
 Biederer, Jürgen [VerfasserIn]   i
Titel:Free breathing 1H MRI of the human lung with an improved radial turbo spin-echo
Verf.angabe:Michael Völker, Philipp Ehses, Stefan Weick, Felix Arno Breuer, Martin Blaimer, Christian Hintze, Jürgen Biederer, Peter Michael Jakob
Jahr:2015
Jahr des Originals:2014
Umfang:12 S.
Fussnoten:Published online: 8 November 2014 ; Gesehen am 12.04.2017
Titel Quelle:Enthalten in: Magnetic resonance materials in physics, biology and medicine
Ort Quelle:Heidelberg : Springer, 1993
Jahr Quelle:2015
Band/Heft Quelle:28(2015), 3, Seite 227-238
ISSN Quelle:1352-8661
Abstract:Objective To optimize a radial turbo spin-echo sequence for motion-robust morphological lung magnetic resonance imaging (MRI) in free respiration.Materials and methods A versatile multi-shot radial turbo spin-echo (rTSE) sequence is presented, using a modified golden ratio-based reordering designed to prevent coherent streaking due to data inconsistencies from physiological motion and the decaying signal. The point spread function for a moving object was simulated using a model for joint respiratory and cardiac motion with a concomitant T2 signal decay and with rTSE acquisition using four different reordering techniques. The reordering strategies were compared in vivo using healthy volunteers and the sequence was tested for feasibility in two patients with lung cancer and pneumonia.ResultsSimulations and in vivo measurements showed very weak artifacts, aside from motion blur, using the proposed reordering. Due to the opportunity for longer scan times in free respiration, a high signal-to-noise ratio (SNR) was achieved, facilitating identification of the disease as compared to standard half-Fourier-acquisition single-shot turbo spin-echo (HASTE) scans. Additionally, post-processing allowed modifying the T2 contrast retrospectively, further improving the diagnostic fidelity.ConclusionThe proposed radial TSE sequence allowed for high-resolution imaging with limited obscuring artifacts. The radial k-space traversal allowed for versatile post-processing that may help to improve the diagnosis of subtle diseases.
DOI:doi:10.1007/s10334-014-0468-x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1007/s10334-014-0468-x
 Volltext: https://link.springer.com/article/10.1007/s10334-014-0468-x
 DOI: https://doi.org/10.1007/s10334-014-0468-x
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1556577354
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68109413   QR-Code
zum Seitenanfang