Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Nonn, Andrea [VerfasserIn]   i
 Kirschner, Stefanie [VerfasserIn]   i
 Brockmann, Marc Alexander [VerfasserIn]   i
Titel:Feasibility, safety, and efficacy of flow-diverting stent-assisted microsphere embolization of fusiform and sidewall aneurysms
Verf.angabe:Andrea Nonn, DVM, Stefanie Kirschner, DVM, Giovanna Figueiredo, MD, Martin Kramer, DVM, Omid Nikoubashman, MD, Rastislav Pjontek, MD, Martin Wiesmann, MD, Marc A. Brockmann, MD
E-Jahr:2015
Jahr:February 14, 2015
Umfang:11 S.
Fussnoten:Gesehen am 29.01.2018
Titel Quelle:Enthalten in: Neurosurgery
Ort Quelle:Alphen aan den Rijn : Wolters Kluwer, 1977
Jahr Quelle:2015
Band/Heft Quelle:77(2015), 1, Seite 126-136
ISSN Quelle:1524-4040
Abstract:Background: Treatment of wide-necked internal carotid artery aneurysms is frequently associated with incomplete occlusion and high recurrence rates. Furthermore, platinum coils cause strong beam-hardening artifacts, hampering subsequent image analyses. Objective: To assess the feasibility, safety, and efficacy of flow-diverting, stent-assisted microsphere embolization of fusiform and sidewall aneurysms in vitro and in vivo. Methods: Using a recirculating pulsatile in vitro flow model, 5 different aneurysm geometries (inner/outer curve, narrow/wide neck, and fusiform) were treated (each n = 1) by flow-diverting stent (FDS) implantation and subsequent embolization through a jailed microcatheter using calibrated microspheres (500-900 μm) larger than the pores of the FDS mesh. Treatment effects were analyzed angiographically and by micro computed tomography. The fluid of the in vitro model was filtered to ensure that no microspheres evaded the aneurysm. The experiment was repeated once in vivo. Results: In vitro, all 5 aneurysms were safely and completely occluded by FDS-assisted microsphere embolization. Virtually complete aneurysm occlusion was confirmed by angiography and micro computed tomography. No microspheres escaped into the circulation. The experiment was successfully repeated in 1 pig with a sidewall aneurysm generated by vessel occlusion. An embolic protection system placed distally of the FDS in vitro and in vivo (each n = 1) contained no microspheres after the embolization. Thus, no microspheres were lost in the circulation, and the use of an embolic protection system seems feasible to provide additional safety. Conclusion: FDS-assisted microsphere embolization of fusiform and sidewall aneurysms is feasible and yields virtually complete aneurysm occlusion while avoiding coil-associated beam-hardening artifacts.
DOI:doi:10.1227/NEU.0000000000000687
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1227/NEU.0000000000000687
 Volltext: https://academic-oup-com.ezproxy.medma.uni-heidelberg.de/neurosurgery/article/77/1/126/2452032
 DOI: https://doi.org/10.1227/NEU.0000000000000687
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1567820166
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68214464   QR-Code
zum Seitenanfang