Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Schmidt, Arthur [VerfasserIn]   i
 Riecken, Bettina [VerfasserIn]   i
 Rische, Susanne [VerfasserIn]   i
 Klinger, Christoph [VerfasserIn]   i
 Jakobs, Ralf [VerfasserIn]   i
 Bechtler, Matthias [VerfasserIn]   i
 Kähler, Georg [VerfasserIn]   i
 Dormann, Arno [VerfasserIn]   i
 Caca, Karel [VerfasserIn]   i
Titel:Wing-shaped plastic stents vs. self-expandable metal stents for palliative drainage of malignant distal biliary obstruction
Titelzusatz:a randomized multicenter study
Verf.angabe:Authors Arthur Schmidt, Bettina Riecken, Susanne Rische, Christoph Klinger, Ralf Jakobs, Matthias Bechtler, Georg Kähler, Arno Dormann, Karel Caca
E-Jahr:2015
Jahr:15.1.2015
Umfang:7 S.
Illustrationen:Illustrationen
Fussnoten:Gesehen am 11.11.2024
Titel Quelle:Enthalten in: Endoscopy
Ort Quelle:Stuttgart [u.a.] : Thieme, 1969
Jahr Quelle:2015
Band/Heft Quelle:47(2015), 5 vom: Mai, Seite 430-436
ISSN Quelle:1438-8812
Abstract:Background and study aims: Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. Patients and methods: A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS. Results: Stent failure occurred in 10/16 patients (62.5%) in the winged-stent group vs. 4/18 patients (22.2%) in the SEMS group (P=0.034). The median time to stent failure was 51 days (range 2–92 days) for the winged stent and 80 days (range 28–266 days) for the SEMS (P=0.002). Early stent failure (<8 weeks after placement) occurred in 8 patients (50%) vs. 2 patients (11.1%), respectively (P=0.022). After obtaining the results from this interim analysis, the study was discontinued because of safety concerns. Conclusions: The frequency of stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction.
DOI:doi:10.1055/s-0034-1391232
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1055/s-0034-1391232
 Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/s-0034-1391232
 Volltext: http://dx.doi.org/10.1055/s-0034-1391232
 Volltext: http://www.thieme-connect.de.ezproxy.medma.uni-heidelberg.de/DOI/DOI?10.1055/s-0034-1391232
 DOI: https://doi.org/10.1055/s-0034-1391232
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1568050976
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68216477   QR-Code
zum Seitenanfang