Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Haubenreisser, Holger [VerfasserIn]  |
| Meyer, Mathias [VerfasserIn]  |
| Janssen, Sonja [VerfasserIn]  |
| Schönberg, Stefan [VerfasserIn]  |
| Henzler, Thomas [VerfasserIn]  |
Titel: | Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100kVp |
Verf.angabe: | Holger Haubenreisser, Mathias Meyer, Sonja Sudarski, Thomas Allmendinger, Stefan O. Schoenberg, Thomas Henzler |
E-Jahr: | 2015 |
Jahr: | August 2015 |
Umfang: | 6 S. |
Fussnoten: | Gesehen am 14.02.2018 |
Titel Quelle: | Enthalten in: European journal of radiology |
Ort Quelle: | Amsterdam [u.a.] : Elsevier Science, 1990 |
Jahr Quelle: | 2015 |
Band/Heft Quelle: | 84(2015), 8, Seite 1608-1613 |
ISSN Quelle: | 1872-7727 |
Abstract: | Objective: To prospectively investigate image quality and radiation dose of 100kVp spectral shaping chest CT using a dedicated tin filter on a 3rd generation dual-source CT (DSCT) in comparison to standard 100kVp chest CT. Methods: Sixty patients referred for a non-contrast chest on a 3rd generation DSCT were prospectively included and examined at 100kVp with a dedicated tin filter. These patients were retrospectively matched with patients that were examined on a 2nd generation DSCT at 100kVp without tin filter. Objective and subjective image quality was assessed in various anatomic regions and radiation dose was compared. Results: Radiation dose was decreased by 90% using the tin filter (3.0 vs 0.32mSv). Soft tissue attenuation and image noise was not statistically different for both examination techniques (p>0.05), however image noise was found to be significantly higher in the trachea when using the additional tin filter (p=0.002). SNR was found to be statistically similar in pulmonary tissue, significantly lower when measured in air and significantly higher in the aorta for the scans on the 3rd generation DSCT. Subjective image quality with regard to overall quality and image noise and sharpness was not statistically significantly different (p>0.05). Conclusion: 100kVp spectral shaping chest CT by means of a tube-based tin-filter on a 3rd generation DSCT allows 90% dose reduction when compared to 100kVp chest CT on a 2nd generation DSCT without spectral shaping. |
DOI: | doi:10.1016/j.ejrad.2015.04.018 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: http://dx.doi.org/10.1016/j.ejrad.2015.04.018 |
| Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X15001928 |
| DOI: https://doi.org/10.1016/j.ejrad.2015.04.018 |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Chest |
| CT |
| Iterative reconstruction |
| Spectral shaping |
K10plus-PPN: | 1569849765 |
Verknüpfungen: | → Zeitschrift |
Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100kVp / Haubenreisser, Holger [VerfasserIn]; August 2015 (Online-Ressource)
68220118