Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Stankova, Vera [VerfasserIn]   i
 Shen, Wei [VerfasserIn]   i
 Briggl, Konrad [VerfasserIn]   i
 Chen, Huangshan [VerfasserIn]   i
 Fischer, Peter [VerfasserIn]   i
 Gil, Alejandro [VerfasserIn]   i
 Harion, Tobias [VerfasserIn]   i
 Kiworra, Volker [VerfasserIn]   i
 Munwes, Yonathan [VerfasserIn]   i
 Ritzert, Michael [VerfasserIn]   i
 Schultz-Coulon, Hans-Christian [VerfasserIn]   i
Titel:STIC3
Titelzusatz:silicon photomultiplier timing chip with picosecond resolution
Verf.angabe:Vera Stankova, Wei Shen, Konrad Briggl, Huangshan Chen, Peter Fischer, Alejandro Gil, Tobias Harion, Volker Kiworra, Yonathan Munwes, Michael Ritzert, Hans-Christian Schultz-Coulon
Umfang:4 S.
Fussnoten:Gesehen am 06.03.2018
Titel Quelle:Enthalten in: Nuclear instruments & methods in physics research / A
Jahr Quelle:2015
Band/Heft Quelle:787(2015), S. 284-287
ISSN Quelle:1872-9576
Abstract:The diagnostic of pancreas and prostate cancer is a challenging task due to the background noise coming from the closer organs. The EndoToFPET-US project aims to combine the synergy between metabolic and anatomical (ultrasound) image in order to improve the precision in the tumor localization. The goal of the project is to develop a Positron Emission Tomography (PET) system that provides a time-of-flight resolution of 200 ps FWHM for improving the signal to noise ratio and further to improve the medical image quality. In order to achieve this purpose an ASIC has been designed for very high timing resolution in time-of-flight (ToF) applications. In this paper we present the ASIC performance and the first characterization measurements with the 64-channels prototype version (STiC3). Measurements are performed with LYSO scintillator crystal and a Multi Pixel Photon Counter (MPPC). Measurements with the chip show an analog-front-end stage jitter of 35 ps for the first photo-electron equivalent charge and reach 18 ps for the third photo-electron. Coincidence time resolution (CTR) of 240 ps FWHM is measured with 3.1×3.1×15 mm3 LYSO crystal and pixel pitch MPPC. Further optimization including the Time-to-Digital Converter (TDC) non-linearity corrections and setup fine tuning are ongoing for achieving the desired CTR of 200 ps FWHM.
DOI:doi:10.1016/j.nima.2014.12.073
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Verlag: http://dx.doi.org/10.1016/j.nima.2014.12.073
 Verlag: https://www.sciencedirect.com/science/article/pii/S0168900214015332
 DOI: https://doi.org/10.1016/j.nima.2014.12.073
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1571771697
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68240241   QR-Code
zum Seitenanfang