Titel: | Detection and removal of ceramic clip markers from breast tissue by ultrasound-guided, vacuum-assisted minimally invasive biopsy in a Turkey breast model |
Verf.angabe: | Benedikt Schaefgen, Jörg Heil, Hannah Richter, Aba Harcos, Christina Gomez, Anne Stieber, Christof Sohn, and Michael Golatta |
Jahr: | 2017 |
Jahr des Originals: | 2016 |
Umfang: | 5 S. |
Fussnoten: | Published online: 20 August 2016 ; Gesehen am 09.04.2018 |
Titel Quelle: | Enthalten in: Ultrasound in medicine & biology |
Ort Quelle: | Amsterdam [u.a.] : Elsevier Science, 1973 |
Jahr Quelle: | 2017 |
Band/Heft Quelle: | 43(2017), 1, Seite 341-345 |
ISSN Quelle: | 1879-291X |
Abstract: | This article explores the ability of sonographically guided, vacuum-assisted minimally invasive biopsy (VAB) to detect and remove ceramic clip markers from breast tissue. This is a feasibility pre-study for a clinical study using vacuum-assisted biopsy to predict pathologic complete response of breast cancer. Twenty-six ceramic clip markers were placed in five turkey breasts. Clip markers were then detected sonographically and removed using VAB by experienced physicians. Quality of visibility was graded by the performing doctors. The specimens were examined macroscopically to see if they contained the clip marker. The main outcome measure was the accuracy of VAB to detect and remove the clip marker. The VAB device was inspected for any damage possibly caused by hitting the clip marker. The clip markers were detected in 25 cases (96.2%). Twenty clip markers (76.9%) were removed completely by VAB and five (19.2%) were partially removed. One clip marker (3.8%) was not removed. On average, detection of the clip marker took 67 s and the biopsy took 178 s. Quality of visibility was mostly graded as very good (14 cases/53.8%) or good (nine cases/34.6%), and in all of these cases the clip marker was at least partially removed. The clip marker was visible and removed in the vast majority of the cases. VAB is able to remove the clip marker in integrity without causing damage to the system. |
DOI: | doi:10.1016/j.ultrasmedbio.2016.08.024 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt. Volltext: http://dx.doi.org/10.1016/j.ultrasmedbio.2016.08.024 |
DOI: https://doi.org/10.1016/j.ultrasmedbio.2016.08.024 | |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | Vacuum-assisted biopsy |
Ceramic clip markers | |
Breast cancer imaging | |
K10plus-PPN: | 1571803270 |
Verknüpfungen: | → Zeitschrift |