Titel:Point shear wave elastography (pSWE) using Acoustic Radiation Force Impulse (ARFI) imaging
Titelzusatz:a feasibility study and norm values for renal parenchymal stiffness in healthy children and adolescents
Verf.angabe:Lilian Grass, Nora Szekely, Abdulsattar Alrajab, Thi Thanh Tam Bui-Ta, Georg Friedrich Hoffmann, Elke Wühl, Jens-Peter Schenk
Jahr:2017
Umfang:8 S.
Fussnoten:Gesehen am 03.05.2018
Titel Quelle:Enthalten in: Medical ultrasonography
Ort Quelle:Timisoara : SRUMB, 2008
Jahr Quelle:2017
Band/Heft Quelle:19(2017), 4, Seite 366-373
ISSN Quelle:2066-8643
Abstract:Aims: To evaluate the applicability of point shear wave elastography (pSWE) for measuring renal parenchymal stiffness in healthy children and adolescents and to establish norm values for shear wave speed (SWS) using two ARFI methods and ultrasound probes.Material and methods: We prospectively investigated 264 children (43.9% males). pSWE (Virtual TouchTM Quantification and Virtual TouchTM Imaging Quantification (VTQ and VTIQ; Siemens, Germany)) was performed in the renal cortex of 528 healthy kidneys using a 1-6 MHz convex and a 4-9 MHz linear ultrasound probe in ventrolateral and dorsal examinations. Feasibility and reproducibility of pSWE measurements were evaluated. SWS values were analysed with regard to age, body dimensions, kidney volume and measuring depth.Results: pSWE measurements were successful in >95% of subjects using the low and in <60% using the high-frequency probe. Mean SWS values (m/s) differed by method and probe: 2.10±0.43 (VTQ1-6MHz, convex, ventrolateral), 2.30±0.37 (VTQ1-6MHz, convex, dorsal), 1.58±0.44 (VTQ4-9MHz, linear, dorsal) and 1.96±0.27 (VTIQ4-9MHz, linear, dorsal). SWS was positively correlated with age, weight and body height, but independent of sex, BMI, or kidney volume and depth.Conclusions: pSWE (VTQ) is a feasible method to evaluate renal parenchymal stiffness in children of all ages. SWS values are age and weight dependent and differ significantly between high- and low-frequency probes. High-frequency probes and VTIQ should only be used in children <10 years.
DOI:doi:10.11152/mu-1078
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.11152/mu-1078
 Volltext: https://www.medultrason.ro/medultrason/index.php/medultrason/article/view/1078
 DOI: https://doi.org/10.11152/mu-1078
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:acoustic radiation force impulse
 children
 kidney
 normal values
 shear wave velocity
K10plus-PPN:1572579293
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68248885   QR-Code
zum Seitenanfang