Verfasst von:Rengier, Fabian [VerfasserIn]   i
 Ley, Sebastian [VerfasserIn]   i
 Müller-Eschner, Matthias [VerfasserIn]   i
 Partovi, Sasan [VerfasserIn]   i
 Geisbüsch, Philipp [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
 Tengg-Kobligk, Hendrik von [VerfasserIn]   i
Titel:In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI
Verf.angabe:Fabian Rengier, Michael Delles, Roland Unterhinninghofen, Sebastian Ley, Matthias Müller-Eschner, Sasan Partovi, Philipp Geisbüsch, Rüdiger Dillmann, Hans-Ulrich Kauczor, Hendrik von Tengg-Kobligk
E-Jahr:2012
Jahr:24 February 2012
Umfang:10 S.
Fussnoten:Gesehen am 17.05.2018
Titel Quelle:Enthalten in: The international journal of cardiovascular imaging
Ort Quelle:Dordrecht [u.a.] : Springer, 1985
Jahr Quelle:2012
Band/Heft Quelle:28(2012), 8, Seite 1999-2008
ISSN Quelle:1875-8312
Abstract:Three-dimensional velocity-encoded cine magnetic resonance imaging (3D VEC MRI) allows for calculation of secondary flow parameters that may be used to estimate prognosis of individual cardiovascular diseases. However, its accuracy has not been fully investigated yet. The purpose of this study was to validate aortic flow quantification by 3D VEC MRI in vitro and in vivo using stacked two-dimensional acquisitions. Time-resolved stacks of two-dimensional planes with three-directional velocity-encoding (stacked-2D-3dir-MRI) were acquired in an elastic tube phantom with pulsatile flow simulating aortic flow as well as in 11 healthy volunteers (23 ± 2 years). Previously validated two-dimensional through-plane VEC MRI at six equidistant levels in vitro and three locations in vivo (ascending aorta/aortic arch/descending aorta) was used as reference standard. The percentage difference of the stacked-2D-3dir-MRI measurement to the reference standard was defined as the parameter for accuracy. For in vitro aortic flow, stacked-2D-3dir-MRI underestimated average velocity by −6.8% (p < 0.001), overestimated average area by 13.6% (p < 0.001), and underestimated average flow by −7.4% (p < 0.001). Accuracy was significantly higher in the field of view centre compared to off-centre (p = 0.001). In vivo, stacked-2D-3dir-MRI underestimated average velocity (all three locations p < 0.001) and overestimated average area at all three locations (p = n.s./<0.001/<0.001). Average flow was significantly underestimated in the ascending aorta (p = 0.035), but tended to be overestimated in the aortic arch and descending aorta. In conclusion, stacked-2D-3dir-MRI tends to overestimate average aortic area and to underestimate average aortic velocity, resulting in significant underestimation of average flow in the ascending aorta.
DOI:doi:10.1007/s10554-012-0027-3
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1007/s10554-012-0027-3
 Volltext: https://link.springer.com/article/10.1007/s10554-012-0027-3
 DOI: https://doi.org/10.1007/s10554-012-0027-3