Titel:Impact of an aortic nitinol stent graft on flow measurements by time-resolved three-dimensional velocity-encoded MRI
Verf.angabe:Fabian Rengier, Michael Delles, Roland Unterhinninghofen, Sebastian Ley, Sasan Partovi, Rüdiger Dillmann, Hans-Ulrich Kauczor, Hendrik von Tengg-Kobligk
Jahr:2012
Umfang:7 S.
Fussnoten:Available online 15 December 2011 ; Gesehen am 17.05.2018
Titel Quelle:Enthalten in: Academic radiology
Ort Quelle:Philadelphia, PA [u.a.] : Elsevier, 1994
Jahr Quelle:2012
Band/Heft Quelle:19(2012), 3, Seite 274-280
ISSN Quelle:1878-4046
Abstract:Rationale and Objectives Three-dimensional (3D) velocity-encoded cine (VEC) magnetic resonance imaging (MRI) has the potential to quantify 3D hemodynamic aspects known from computational fluid dynamics and to be used to identify hemodynamic risk factors for complications of endovascular aortic repair. The purpose of this study was to investigate the impact of an aortic nickel-titanium (nitinol) stent graft on the accuracy of flow measurements by 3D VEC MRI. Materials and Methods A pump generated pulsatile aortic flow in an elastic tube phantom mimicking the aorta. Stacked two-dimensional three-directional VEC MRI (stacked-2D-3dir-MRI), 3D three-directional VEC MRI (3D-3dir-MRI), and gold-standard 2D through-plane VEC MRI were applied before and after the insertion of an aortic nitinol stent graft. Six equidistant levels were analyzed twice by the same reader. The percentage difference of the measured flow rate from the gold standard was defined as the parameter of accuracy. Results The overall accuracy of in-stent flow measurements related to the gold standard was −5.4% for stacked-2D-3dir-MRI and −4.1% for 3D-3dir-MRI, demonstrating significant overall underestimation compared to the gold standard (P = .016 and P = .013). However, flow measurements with the stent graft were significantly overestimated by 4.1% using stacked-2D-3dir-MRI (P < .001) and by 5.4% using 3D-3dir-MRI (P = .003) compared to identical measurements without the stent graft. In stacked-2D-3dir-MRI, this positive bias was significantly greater at the proximal and distal ends of the stent graft (P = .025). In 3D-3dir-MRI, measurements along the whole length of the stent graft were affected (P = .006). Intraobserver agreement was excellent, with intraclass correlation coefficients of 0.94 for stacked-2D-3dir-MRI (P < .001) and 0.90 for 3D-3dir-MRI (P < .001). Conclusions Flow measurements within an aortic nitinol stent graft by 3D VEC MRI are feasible, but stent grafts may cause a significant positive bias.
DOI:doi:10.1016/j.acra.2011.10.025
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1016/j.acra.2011.10.025
 Volltext: http://www.sciencedirect.com/science/article/pii/S1076633211005125
 DOI: https://doi.org/10.1016/j.acra.2011.10.025
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:aorta
 blood flow
 Magnetic resonance imaging
 stent graft
 three-dimensional imaging