| Online-Ressource |
Verfasst von: | Gabbert, Olaf [VerfasserIn]  |
| Karatzogiannis, Efstathios [VerfasserIn]  |
| Ohlmann, Brigitte [VerfasserIn]  |
| Schmitter, Marc [VerfasserIn]  |
| Karl, Jochen [VerfasserIn]  |
| Rammelsberg, Peter [VerfasserIn]  |
Titel: | Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses |
Titelzusatz: | effect of span length and preparation design |
Verf.angabe: | Olaf Gabbert, Efstathios Karatzogiannis, Brigitte Ohlmann, Marc Schmitter, Jochen Karl, Peter Rammelsberg |
Jahr: | 2012 |
Jahr des Originals: | 2011 |
Umfang: | 7 S. |
Fussnoten: | First published: 03 August 2011 ; Gesehen am 05.06.2018 |
Titel Quelle: | Enthalten in: Clinical oral implants research |
Ort Quelle: | Oxford : Wiley-Blackwell, 1990 |
Jahr Quelle: | 2012 |
Band/Heft Quelle: | 23(2012), 6, Seite 719-725 |
ISSN Quelle: | 1600-0501 |
Abstract: | Objectives: Evaluation of the effect of different span length and preparation designs on the fracture load of tooth-implant-supported fixed dental prostheses (TIFDPs) manufactured from yttrium-stabilized zirconia frameworks. Material and methods: Forty-eight TIFDPs were manufactured using a CAD/CAM system and veneered with a press ceramic. Rigidly mounted implants (SLA, diameter 4.1 mm, length 10 mm) in the molar region with a titanium abutment were embedded in PMMA bases pairwise with premolars. All premolars were covered with heat-shrink tubing to simulate physiological tooth mobility. Six different test groups were prepared (a) differing in the preparation design of the premolar (inlay [i]; crown [c]), (b) the material of the premolar (metal [m]; natural human [h]) and (c) the length of the TIFDPs (3-unit [3]; 4-unit [4]). All TIFDPs underwent thermomechanical loading (TCML) (10,000 × 6.5°/60°; 6 × 105× 50 N). The load to fracture (N) was measured and fracture sites were evaluated macroscopically. Results: None of the restorations failed during TCML. The mean fracture loads (standard deviations) were 1,522 N (249) for the 3-unit, inlay-retained TIFDPs on a metal abutment tooth (3-im), 1,910 N (165) for the 3-cm group, 1,049 N (183) for group 4-im, 1,274 N (282) for group 4-cm, 1,229 N (174) for group 4-ih and 911 N (205) for group 4-ch. Initial damages within the veneering ceramic occurred before the final failure of the restoration. The corresponding loads were 24-52% lower than the fracture load values. Conclusions: All restorations tested could withstand the mastication forces expected. Fracture-load values for 3- and 4-unit inlay-crown and crown-crown-retained TIFDPs should spur further clinical investigation. |
DOI: | doi:10.1111/j.1600-0501.2011.02191.x |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: http://dx.doi.org/10.1111/j.1600-0501.2011.02191.x |
| Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1600-0501.2011.02191.x |
| DOI: https://doi.org/10.1111/j.1600-0501.2011.02191.x |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | all-ceramic suprastructures |
| combined tooth-implant-supported FDPs |
| dental implants |
| fixed dental prostheses |
| in vitro |
| rigid and non-rigid connection |
| splinting |
| tooth-implant connection |
| zirconia ceramic |
K10plus-PPN: | 1575993775 |
Verknüpfungen: | → Zeitschrift |
Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses / Gabbert, Olaf [VerfasserIn]; 2012 (Online-Ressource)