Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Gabbert, Olaf [VerfasserIn]   i
 Karatzogiannis, Efstathios [VerfasserIn]   i
 Ohlmann, Brigitte [VerfasserIn]   i
 Schmitter, Marc [VerfasserIn]   i
 Karl, Jochen [VerfasserIn]   i
 Rammelsberg, Peter [VerfasserIn]   i
Titel:Fracture load of tooth-implant-retained zirconia ceramic fixed dental prostheses
Titelzusatz:effect of span length and preparation design
Verf.angabe:Olaf Gabbert, Efstathios Karatzogiannis, Brigitte Ohlmann, Marc Schmitter, Jochen Karl, Peter Rammelsberg
Jahr:2012
Jahr des Originals:2011
Umfang:7 S.
Fussnoten:First published: 03 August 2011 ; Gesehen am 05.06.2018
Titel Quelle:Enthalten in: Clinical oral implants research
Ort Quelle:Oxford : Wiley-Blackwell, 1990
Jahr Quelle:2012
Band/Heft Quelle:23(2012), 6, Seite 719-725
ISSN Quelle:1600-0501
Abstract:Objectives: Evaluation of the effect of different span length and preparation designs on the fracture load of tooth-implant-supported fixed dental prostheses (TIFDPs) manufactured from yttrium-stabilized zirconia frameworks. Material and methods: Forty-eight TIFDPs were manufactured using a CAD/CAM system and veneered with a press ceramic. Rigidly mounted implants (SLA, diameter 4.1 mm, length 10 mm) in the molar region with a titanium abutment were embedded in PMMA bases pairwise with premolars. All premolars were covered with heat-shrink tubing to simulate physiological tooth mobility. Six different test groups were prepared (a) differing in the preparation design of the premolar (inlay [i]; crown [c]), (b) the material of the premolar (metal [m]; natural human [h]) and (c) the length of the TIFDPs (3-unit [3]; 4-unit [4]). All TIFDPs underwent thermomechanical loading (TCML) (10,000 × 6.5°/60°; 6 × 105× 50 N). The load to fracture (N) was measured and fracture sites were evaluated macroscopically. Results: None of the restorations failed during TCML. The mean fracture loads (standard deviations) were 1,522 N (249) for the 3-unit, inlay-retained TIFDPs on a metal abutment tooth (3-im), 1,910 N (165) for the 3-cm group, 1,049 N (183) for group 4-im, 1,274 N (282) for group 4-cm, 1,229 N (174) for group 4-ih and 911 N (205) for group 4-ch. Initial damages within the veneering ceramic occurred before the final failure of the restoration. The corresponding loads were 24-52% lower than the fracture load values. Conclusions: All restorations tested could withstand the mastication forces expected. Fracture-load values for 3- and 4-unit inlay-crown and crown-crown-retained TIFDPs should spur further clinical investigation.
DOI:doi:10.1111/j.1600-0501.2011.02191.x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1111/j.1600-0501.2011.02191.x
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1600-0501.2011.02191.x
 DOI: https://doi.org/10.1111/j.1600-0501.2011.02191.x
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:all-ceramic suprastructures
 combined tooth-implant-supported FDPs
 dental implants
 fixed dental prostheses
 in vitro
 rigid and non-rigid connection
 splinting
 tooth-implant connection
 zirconia ceramic
K10plus-PPN:1575993775
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68257724   QR-Code
zum Seitenanfang