Navigation überspringen
Universitätsbibliothek Heidelberg
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Rieger, Benedikt [VerfasserIn]   i
 Weingärtner, Sebastian [VerfasserIn]   i
 Schad, Lothar R. [VerfasserIn]   i
Titel:Time efficient whole-brain coverage with MR fingerprinting using slice-interleaved echo-planar-imaging
Verf.angabe:Benedikt Rieger, Mehmet Akçakaya, José C. Pariente, Sara Llufriu, Eloy Martinez-Heras, Sebastian Weingärtner & Lothar R. Schad
Jahr:2018
Umfang:12 S.
Fussnoten:Published online: 27 April 2018 ; Gesehen am 14.06.2018
Titel Quelle:Enthalten in: Scientific reports
Ort Quelle:[London] : Macmillan Publishers Limited, part of Springer Nature, 2011
Jahr Quelle:2018
Band/Heft Quelle:8(2018) Artikel-Nummer 6667, 12 Seiten
ISSN Quelle:2045-2322
Abstract:Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T1 and T2* maps with integrated B1+ correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T1: −2.4 ± 1.1%, T2*: −0.5 ± 2.5%, PD: −0.5 ± 7.2%). In-vivo whole-brain coverage of T1, T2* and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.
DOI:doi:10.1038/s41598-018-24920-z
URL:Kostenfrei: Volltext ; Verlag: http://dx.doi.org/10.1038/s41598-018-24920-z
 Kostenfrei: Volltext: https://www.nature.com/articles/s41598-018-24920-z
 DOI: https://doi.org/10.1038/s41598-018-24920-z
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:157636741X
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68261200   QR-Code
zum Seitenanfang