Titel:Quantification of left and right ventricular function and myocardial mass
Titelzusatz:comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI
Verf.angabe:Richard A.P. Takx, Antonio Moscariello, U. Joseph Schoepf, J. Michael Barraza, John W. Nance, Gorka Bastarrika, Marco Das, Mathias Meyer, Joachim E. Wildberger, Stefan O. Schoenberg, Christian Fink, Thomas Henzler
Jahr des Originals:2011
Umfang:7 S.
Fussnoten:Available online 9 August 2011 ; Gesehen am 27.06.2018
Titel Quelle:Enthalten in: European journal of radiology
Jahr Quelle:2012
Band/Heft Quelle:81(2012), 4, S. e598-e604
ISSN Quelle:1872-7727
Abstract:Objective To prospectively evaluate the accuracy of left and right ventricular function and myocardial mass measurements based on a dual-step, low radiation dose protocol with prospectively ECG-triggered 2nd generation dual-source CT (DSCT), using cardiac MRI (cMRI) as the reference standard. Materials and methods Twenty patients underwent 1.5 T cMRI and prospectively ECG-triggered dual-step pulsing cardiac DSCT. This image acquisition mode performs low-radiation (20% tube current) imaging over the majority of the cardiac cycle and applies full radiation only during a single adjustable phase. Full-radiation-phase images were used to assess cardiac morphology, while low-radiation-phase images were used to measure left and right ventricular function and mass. Quantitative CT measurements based on contiguous multiphase short-axis reconstructions from the axial CT data were compared with short-axis SSFP cardiac cine MRI. Contours were manually traced around the ventricular borders for calculation of left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction and myocardial mass for both modalities. Statistical methods included independent t-tests, the Mann-Whitney U test, Pearson correlation statistics, and Bland-Altman analysis. Results All CT measurements of left and right ventricular function and mass correlated well with those from cMRI: for left/right end-diastolic volume r = 0.885/0.801, left/right end-systolic volume r = 0.947/0.879, left/right stroke volume r = 0.620/0.697, left/right ejection fraction r = 0.869/0.751, and left/right myocardial mass r = 0.959/0.702. Mean radiation dose was 6.2 ± 1.8 mSv. Conclusions Prospectively ECG-triggered, dual-step pulsing cardiac DSCT accurately quantifies left and right ventricular function and myocardial mass in comparison with cMRI with substantially lower radiation exposure than reported for traditional retrospective ECG-gating.
DOI:doi:10.1016/j.ejrad.2011.07.001
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Verlag: http://dx.doi.org/10.1016/j.ejrad.2011.07.001
 Verlag: https://www.ejradiology.com/article/S0720-048X(11)00601-2/abstract
 DOI: https://doi.org/10.1016/j.ejrad.2011.07.001
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1576896641
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68274778   QR-Code
zum Seitenanfang