Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Ritter, Manuel [VerfasserIn]   i
 Krombach, Patrick [VerfasserIn]   i
 Martinschek, Andreas [VerfasserIn]   i
 Siegel, Fabian [VerfasserIn]   i
 Weiß, Christel [VerfasserIn]   i
 Häcker, Axel [VerfasserIn]   i
 Pelzer, Alexandre E. [VerfasserIn]   i
Titel:Radiation exposure during endourologic procedures using over-the-table fluoroscopy sources
Verf.angabe:Manuel Ritter, Patrick Krombach, Andreas Martinschek, Fabian P. Siegel, Martin Schmitt, Christel Weiss, Axel Häcker, and Alexandre E. Pelzer
Jahr:2012
Umfang:5 S.
Fussnoten:Published online:4 Jan 2012 ; Gesehen am 28.06.2018
Titel Quelle:Enthalten in: Journal of endourology
Ort Quelle:Larchmont, NY : Liebert, 1999
Jahr Quelle:2012
Band/Heft Quelle:26(2012), 1, Seite 47-51
ISSN Quelle:1557-900X
Abstract:Background and Purpose: Fluoroscopy is used daily by endourologic surgeons worldwide without knowledge of received radiation doses. We wanted to assess the radiation exposure of endourologic surgeons by frequently performed endourologic interventions with an over-the-table x-ray system.Patients and Methods: In this prospective single-center study, 235 endourologic interventions in 188 patients from April to September 2010 were included. Sixty-seven ureteral stent placements (USP), 51 ureteral stent changes (USC), 67 percutaneous stent changes (PSC), 11 percutaneous nephrolithotomies (PCNL), and 39 ureterorenoscopies (URS) were performed by 12 surgeons. The surgeon`s radiation exposure was measured with one thermoluminescent dosimeter (TLD) at the forehead and one at the ring finger. TLDs were analyzed at a central institute. The radiation dose detected at the forehead was counted as representative for the lens of the eye and the thyroid.Results: Mean patient age was 60.6 (±18.8) years. Analysis of the TLD showed the following average values at the forehead for each intervention: USP and USC 0.04 mSv; PSC 0.03 mSv; PCNL 0.18 mSv; URS 0.1 mSv. Average finger values are: USP 0.13 mSv; USC 0.21 mSv; PSC 0.20 mSv; PCNL 4.36 mSv; URS 0.15 mSv.Conclusions: This report evaluates surgeons' radiation exposure by everyday endourologic interventions of different complexity. Most can be performed with an over-the-table x-ray system without exceeding statutory limits. Especially for PCNL, surgeons should consider possible protective action.
DOI:doi:10.1089/end.2011.0333
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1089/end.2011.0333
 Volltext: https://www.liebertpub.com/doi/abs/10.1089/end.2011.0333
 DOI: https://doi.org/10.1089/end.2011.0333
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1577001060
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68275414   QR-Code
zum Seitenanfang