Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Lyu, P. [VerfasserIn]   i
 Herrmann, Norbert [VerfasserIn]   i
 Deppner, Ingo Martin [VerfasserIn]   i
 Simon, Christian [VerfasserIn]   i
 Weidenkaff, Philipp [VerfasserIn]   i
Titel:Development and performance of self-sealed MRPC
Verf.angabe:P. Lyu, Y. Wang, B. Guo, D. Han, Y. Li, N. Herrmann, I. Deppner, C. Simon, P. Weidenkaff, F. Jochen, P.-A. Loizeau and M. Laden Kis
E-Jahr:2017
Jahr:14 March 2017
Umfang:? S.
Fussnoten:Gesehen am 05.07.2018 ; 14th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD16)
Titel Quelle:Enthalten in: Journal of Instrumentation
Ort Quelle:London : Inst. of Physics, 2006
Jahr Quelle:2017
Band/Heft Quelle:12(2017,3) Artikel-Nummer C03055
ISSN Quelle:1748-0221
Abstract:The MRPC has been widely applied in the high-energy physics experiments in recent decades for its excellent timing performance and good efficiency. The Compressed Baryonic Matter (CBM) experiment at FAIR plans to build its TOF system based on the MRPCs, aiming at a good hadron identification. The CBM-TOF will work at a very high particle flux rate ( 30 kHz/cm 2 ) condition, and the long-time exposure to such high-rate ionizing radiation will lead to severe gas aging problem on the MRPC. In order to improve the gas interchange inside the MRPC, we designed a new structure of self-sealed MRPC. It has a much smaller gas volume, which may accelerate the exchange process between the fresh and the polluted gas. The preparation time before the MRPC could work is also largely shortened. A prototype of self-sealed MRPC was produced in Tsinghua University, and it was tested in the CERN SPS Nov 2015 beam test organized by the CBM-TOF group. It showed around 98% efficiency and 60 ps time resolution. Due to the rate limit of 10 kHz/cm 2 in this beam test, we cannot make judgement on its performance under extremely high rate. Therefore further studies have to be performed under higher rate in order to study the capability of improving the gas exchange speed of this more flexible and operable sealed MRPC. This will allow that MRPC to be better suited for the high rate environment of TOF system while operating in the experiment.
DOI:doi:10.1088/1748-0221/12/03/C03055
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1088/1748-0221/12/03/C03055
 Volltext: http://stacks.iop.org/1748-0221/12/i=03/a=C03055
 DOI: https://doi.org/10.1088/1748-0221/12/03/C03055
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1577322150
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68282775   QR-Code
zum Seitenanfang