Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Handrack, Josefine [VerfasserIn]   i
 Tessonnier, Thomas [VerfasserIn]   i
 Chen, Wenjing [VerfasserIn]   i
 Liebl, Jakob [VerfasserIn]   i
 Debus, Jürgen [VerfasserIn]   i
 Bauer, Julia [VerfasserIn]   i
 Parodi, Katia [VerfasserIn]   i
Titel:Sensitivity of post treatment positron emission tomography/computed tomography to detect inter-fractional range variations in scanned ion beam therapy
Verf.angabe:Josefine Handrack, Thomas Tessonnier, Wenjing Chen, Jakob Liebl, Jürgen Debus, Julia Bauer & Katia Parodi
E-Jahr:2017
Jahr:18 Sep 2017
Umfang:9 S.
Fussnoten:Gesehen am 12.07.2018
Titel Quelle:Enthalten in: Acta oncologica
Ort Quelle:Abingdon : Taylor & Francis Group, 1987
Jahr Quelle:2017
Band/Heft Quelle:56(2017), 11, Seite 1451-1458
ISSN Quelle:1651-226X
Abstract:Background: Ion therapy, especially with modern scanning beam delivery, offers very sharp dose gradients for highly conformal cancer treatment. However, it is very sensitive to uncertainties of tissue stopping properties as well as to anatomical changes and setup errors, making range verification highly desirable. To this end, positron emission tomography (PET) can be used to measure decay products of bþ-emitters created in interactions inside the patient. This work investigates the sensitivity of post treatment PET/CT (computed tomography) to detect inter-fractional range variations. Material and methods: Fourteen patients of different indication underwent PET/CT monitoring after selected treatment fractions with scanned proton or carbon ion beams. In addition to PET/CT measurements, PET and dose distributions were simulated on different co-registered CT data. Pairs of PET data were then analyzed in terms of longitudinal shifts along the beam path, as surrogate of inter-fractional range deviations. These findings were compared to changes of dose-volume-histogram indexes and corresponding dose as well as CT shifts to disentangle the origin of possible PET shifts. Results: Biological washout modeling (PET simulations) and low (<55 Bq/ml) activity concentrations (offline PET measurements, especially for 12C ions) were the main limitations for clinical treatment verification. For two selected cases, the benefit of improved washout modeling based on organ segmentation could be demonstrated. Overall, inter-fractional range shifts up to ±3 mm could be deduced from both PET measurements and simulations, and found well correlated (typically within 1.8 mm) to anatomical changes derived from CT scans, in agreement with dose data. Conclusions: Despite known limitations of post treatment PET/CT imaging, this work indicates its potential for assessing inter-fractional changes and points to future developments for improved PETbased treatment verification.
DOI:doi:10.1080/0284186X.2017.1348628
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1080/0284186X.2017.1348628
 Volltext: https://www.tandfonline.com/doi/full/10.1080/0284186X.2017.1348628
 DOI: https://doi.org/10.1080/0284186X.2017.1348628
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1577552180
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68285042   QR-Code