Online-Ressource | |
Verfasst von: | Vonder, Marleen [VerfasserIn] |
Meyer, Mathias [VerfasserIn] | |
Henzler, Thomas [VerfasserIn] | |
Titel: | Feasibility of spectral shaping for detection and quantification of coronary calcifications in ultra-low dose CT |
Verf.angabe: | Marleen Vonder, Gert Jan Pelgrim, Sèvrin E. M. Huijsse, Mathias Meyer, Marcel J. W. Greuter, Thomas Henzler, Thomas G. Flohr, Matthijs Oudkerk, Rozemarijn Vliegenthart |
Jahr des Originals: | 2016 |
Umfang: | 8 S. |
Fussnoten: | Published online: 29 August 2016 ; Gesehen am 20.07.2018 |
Titel Quelle: | Enthalten in: European radiology |
Jahr Quelle: | 2017 |
Band/Heft Quelle: | 27(2017), 5, S. 2047-2054 |
ISSN Quelle: | 1432-1084 |
1613-3757 | |
Abstract: | ObjectivesTo evaluate detectability and quantification of coronary calcifications for CT with a tin filter for spectral shaping.MethodsPhantom inserts with 100 small and 9 large calcifications, and a moving artificial artery with 3 calcifications (speed 0-30 mm/s) were placed in a thorax phantom simulating different patient sizes. The phantom was scanned in high-pitch spiral mode at 100 kVp with tin filter (Sn100 kVp), and at a reference of 120 kVp, with electrocardiographic (ECG) gating. Detectability and quantification of calcifications were analyzed for standard (130 HU) and adapted thresholds.ResultsSn100 kVp yielded lower detectability of calcifications (9 % versus 12 %, p = 0.027) and lower Agatston scores (p < 0.008), irrespective of calcification, patient size and speed. Volume scores of the moving calcifications for Sn100 kVp at speed 10-30 mm/s were lower (p < 0.001), while mass scores were similar (p = 0.131). For Sn100 kVp with adapted threshold of 117 HU, detectability (p = 1.000) and Agatston score (p > 0.206) were similar to 120 kVp. Spectral shaping resulted in median dose reduction of 62.3 % (range 59.0-73.4 %).ConclusionsCoronary calcium scanning with spectral shaping yields lower detectability of calcifications and lower Agatston scores compared to 120 kVp scanning, for which a HU threshold correction should be developed. Key points • Sn100kVp yields lower detectability and lower Agatston scores compared to 120kVp • Adapted HU threshold for Sn100kVp provides Agatston scores comparable to 120kVp • Sn100 kVp considerably reduces dose in calcium scoring versus 120 kVp |
DOI: | doi:10.1007/s00330-016-4507-z |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt. Verlag: http://dx.doi.org/10.1007/s00330-016-4507-z |
Verlag: https://link.springer.com/article/10.1007/s00330-016-4507-z | |
DOI: https://doi.org/10.1007/s00330-016-4507-z | |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1577804430 |
Verknüpfungen: | → Zeitschrift |