Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Müller, Philip C. [VerfasserIn]   i
 Steinemann, Daniel [VerfasserIn]   i
 Sauer, Peter [VerfasserIn]   i
 Z’graggen, Kaspar [VerfasserIn]   i
 Linke, Georg R. [VerfasserIn]   i
 Müller, Beat P. [VerfasserIn]   i
Titel:Balloon Dilatation of the Minor Duodenal Papilla Up to 4 mm is Safe in a Porcine Model
Verf.angabe:Philip C. Müller, Daniel C. Steinemann, Peter Sauer, Kaspar Z’graggen, Georg R. Linke, Beat P. Müller-Stich
Jahr:2017
Umfang:4 S.
Fussnoten:Gesehen am 13.08.2018
Titel Quelle:Enthalten in: Surgical laparoscopy, endoscopy & percutaneous techniques
Ort Quelle:Hagerstown, Md. : Lippincott Williams & Wilkins, 1991
Jahr Quelle:2017
Band/Heft Quelle:27(2017), 4, Seite e44-e47
ISSN Quelle:1534-4908
Abstract:Objectives: Balloon dilatation of the minor duodenal papilla is a treatment option for symptomatic pancreas divisum. The histologic effects of balloon dilatation have not yet been evaluated. The aim of this study is to investigate the tolerated extent of dilatation of the minor papilla. Materials and Methods: A dilatation of the minor papilla was performed in freshly explanted pancreas of pigs using biliary balloon dilatators. Three organs were not dilated (control group), in each 8 organs a dilatation of 4, 6, and 8 mm, respectively, was performed. Tissue damage was assessed by microscopic evaluation. Ductal wall disruption and perforation as well as a semiquantitative inflammation score was described and compared. Results: Ductal wall disruption was increased by dilatation of 6 (5/8; P=0.019) and 8 mm (6/8; P=0.006) compared with 4 mm (1/8). Median inflammation score was 0 (0 to 0), 1 (0 to 2), and 1 (0 to 2) for dilatation of 4, 6, and 8 mm, respectively (4 vs. 6 mm, P=0.007; 4 vs. 8 mm, P=0.026). No perforation occurred in the 4 (0/8) and 6 mm (0/8) group, 1 perforation occurred in the 8 mm group (1/8). Conclusions: A dilatation of up to 4 mm seems to be safe. However, dilatation of the minor papilla from 4 mm onwards is increasingly associated with tissue damage. These findings should be considered in endoscopic procedures dilating the minor duodenal papilla.
DOI:doi:10.1097/SLE.0000000000000414
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://journals.lww.com/surgical-laparoscopy/Abstract/2017/08000/Balloon_Dilatation_of_the_Minor_Duodenal_Papilla.19.as ...
 Volltext: http://dx.doi.org/10.1097/SLE.0000000000000414
 DOI: https://doi.org/10.1097/SLE.0000000000000414
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1578508428
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68294884   QR-Code
zum Seitenanfang