Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Müller, Ulrike [VerfasserIn]   i
 Braun, Steffen [VerfasserIn]   i
 Schröder, Stefan [VerfasserIn]   i
 Sonntag, Robert [VerfasserIn]   i
 Kretzer, Jan Philippe [VerfasserIn]   i
Titel:Same same but different?
Titelzusatz:12/14 stem and head tapers in total hip arthroplasty
Verf.angabe:Ulrike Mueller, Steffen Braun, Stefan Schroeder, Robert Sonntag, J. Philippe Kretzer
E-Jahr:2017
Jahr:27 April 2017
Umfang:9 S.
Fussnoten:Gesehen am 15.08.2018
Titel Quelle:Enthalten in: The journal of arthroplasty
Ort Quelle:Orlando, Fla. : Churchill Livingstone, 1986
Jahr Quelle:2017
Band/Heft Quelle:32(2017), 10, Seite 3191-3199
ISSN Quelle:1532-8406
Abstract:Background: Taper corrosion has been identified to be a major concern in total hip arthroplasty during the past years. So far, the mechanisms that lead to taper corrosion in modular taper junctions are not fully understood. However, it has been shown that corrosion is also influenced by the geometry and topography of the taper, and these parameters vary among the implant manufacturers. The purpose of this study was to investigate the variations of common stem and head tapers regarding design and surface characteristics. Methods: An analysis of selected commercially available 12/14 stem and head tapers was performed. As geometric parameters, the taper angle, the opening taper diameter, and the taper length were measured using a coordinate measuring machine. Several topographic parameters were determined using a tactile roughness measurement instrument. Results: Although all investigated tapers are so-called 12/14 tapers, this study showed that the stem and head tapers differ among the manufacturers. The stem tapers were clearly different in both geometry and topography, and the range in variation of the topographic parameter was greater than it was for the geometric parameter. In contrast, the head tapers were different in their geometry, although not in topography. Conclusion: Ultimately, this study provides an overview on the characteristics and variations of modular hip taper connections, and in addition, a new classification system regarding the surface finish is presented. These findings could be further considered in experimental corrosion or retrieval studies.
DOI:doi:10.1016/j.arth.2017.04.027
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1016/j.arth.2017.04.027
 Volltext: http://www.sciencedirect.com/science/article/pii/S0883540317303492
 DOI: https://doi.org/10.1016/j.arth.2017.04.027
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:corrosion
 head-stem junction
 modularity
 taper
 topography
 total hip arthroplasty (THA)
K10plus-PPN:1580058957
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68295688   QR-Code
zum Seitenanfang