Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Maier, Michael Wolfgang [VerfasserIn]   i
 Erhard, Sarah [VerfasserIn]   i
 Thielen, Mirjam [VerfasserIn]   i
 Bruckner, Thomas [VerfasserIn]   i
 Wolf, Sebastian Immanuel [VerfasserIn]   i
 Zeifang, Felix [VerfasserIn]   i
 Raiss, Patric [VerfasserIn]   i
Titel:Three-dimensional motion analysis for validation of shoulder internal rotation
Verf.angabe:Michael W. Maier, Sarah Erhard, Mirjam Niklasch, Thomas Bruckner, Sebastian I. Wolf, Felix Zeifang, Patric Raiss
E-Jahr:2017
Jahr:04 April 2017
Umfang:7 S.
Fussnoten:Gesehen am 16.08.2018
Titel Quelle:Enthalten in: Archives of orthopaedic and trauma surgery
Ort Quelle:Berlin : Springer, 1903
Jahr Quelle:2017
Band/Heft Quelle:137(2017), 6, Seite 735-741
ISSN Quelle:1434-3916
Abstract:Background10% of the points for the Constant-Murley score (CMS) are allocated for the capacity for internal rotation (IR), measured as unassisted active movement of the dorsum of the hand or the thumb to reach different anatomical landmarks. However, there is little information about the validity of this method and no three-dimensional measurement of the degree of IR that is necessary to reach these landmarks.MethodsSixteen volunteers with healthy shoulders were recruited. The degree of IR was defined using the following landmarks as described in the CMS: (1) lateral aspect of thigh, (2) buttock, (3) sacroiliac joint, (4) level of waist, (5) vertebra T12, (6) interscapular. The validity of IR measurement was assessed by simultaneous 3D motion analysis.ResultsUsing the thumb as pointer, there were significant increases in IR from 39.3° at position 1 to 80.4° at position 2, followed by 105.1°, 108.6°, 110.1°, and 125.3° at position 3-6. Taking the dorsum of the hand as pointer, there were significant increases in IR between all positions, starting from 71.2° (position 1) and followed by 99.3°, 104.1°, 110.3°, 115.2°, and 119.7° at positions 2 to 6. Comparing the two measurement methods, a significant difference was found for the amount of IR between positions 1 and 2.ConclusionMeasurement of IR as described in the CMS is a suitable method. However, there was an increase of only 10° in IR between positions 3 and 5, which may be hard to measure with a standard goniometer in clinical practice.
DOI:doi:10.1007/s00402-017-2656-4
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1007/s00402-017-2656-4
 Volltext: https://link.springer.com/article/10.1007/s00402-017-2656-4
 DOI: https://doi.org/10.1007/s00402-017-2656-4
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1580108083
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68296101   QR-Code
zum Seitenanfang