Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Attia, Mary [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
 Kretz, Florian Tobias Alwin [VerfasserIn]   i
 Tandogan, Tamer [VerfasserIn]   i
 Rabsilber, Tanja Marina [VerfasserIn]   i
 Holzer, Mike P. [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
Titel:Clinical evaluation of an extended depth of focus intraocular lens with the Salzburg reading desk
Verf.angabe:Mary S.A. Attia, Gerd U. Auffarth, Florian T.A. Kretz, Tamer Tandogan, Tanja M. Rabsilber, Mike P. Holzer, Ramin Khoramnia
E-Jahr:2017
Jahr:October 10, 2017
Umfang:6 S.
Fussnoten:Gesehen am 21.08.2018
Titel Quelle:Enthalten in: Journal of refractive surgery
Ort Quelle:Thorofare, NJ : SLACK Inc., 1996
Jahr Quelle:2017
Band/Heft Quelle:33(2017), 10, Seite 664-669
ISSN Quelle:1938-2391
Abstract:BACKGROUND: Clinical evaluation of an extended depth of focus (EDOF) intraocular lens (IOL) regarding visual performance at various distances, reading performance on an electronic reading desk, and depth of focus on the defocus curve. METHODS: In this prospective study, 30 eyes of 15 patients who received the Tecnis Symfony IOL (Abbott Medical Optics, Inc., Santa Ana, CA) were examined 3.60 ± 1.54 months postoperatively. Uncorrected and corrected distance (UDVA and CDVA), uncorrected and distance-corrected intermediate (UIVA and DCIVA), and uncorrected and distance-corrected near (UNVA and DCNVA) visual acuity were determined. The defocus curve was performed with distance correction. Furthermore, the reading acuity at the preferred near and intermediate distances was measured with consideration of the reading distance, speed, and print size. A subjective questionnaire was also administered. RESULTS: Results showed a median UDVA of 0.03 logMAR or 20/21.43 Snellen (range: 0.44 to -0.18 logMAR or 20/55.08 to 20/13.21 Snellen), UNVA of 0.20 logMAR or 20/31.70 Snellen (range: 0.46 to 0.00 logMAR or 20/57.68 to 20/20 Snellen), and UIVA of -0.03 logMAR or 20/18.67 Snellen (range: 0.14 to -0.18 logMAR or 20/27.61 to 20/13.21 Snellen). The improved performance at intermediate distance was confirmed by an uncorrected reading acuity of 0.09 logMAR or 20/24.61 Snellen (range: 0.36 to 0.00 logMAR or 20/45.82 to 20/20.00 Snellen) at a preferred intermediate distance of 64.10 cm (range: 52.0 to 75.0 cm). The defocus curve showed an extended range of visual acuity of 0.10 logMAR or better between 1.00 and -1.50 diopters. CONCLUSIONS: The EDOF IOL design provided a wide range of improved visual and reading function between far and intermediate distances and also improved near visual acuity. Patients reported a high rate of satisfaction and spectacle independence at the various distances. [J Refract Surg. 2017;33(10):664-669.].
DOI:doi:10.3928/1081597X-20170621-08
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.3928/1081597X-20170621-08
 DOI: https://doi.org/10.3928/1081597X-20170621-08
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Aged
 Cataract
 Female
 Humans
 Lenses, Intraocular
 Male
 Middle Aged
 Postoperative Period
 Prospective Studies
 Prosthesis Design
 Pseudophakia
 Reading
 Refraction, Ocular
 Surveys and Questionnaires
 Vision Tests
 Vision, Binocular
 Visual Acuity
K10plus-PPN:1580243428
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68297440   QR-Code
zum Seitenanfang