Verfasst von:Khoramnia, Ramin [VerfasserIn]   i
 Salgado, Josefina Susana Parente [VerfasserIn]   i
 Lohmann, Chris P. [VerfasserIn]   i
Titel:Precision, morphology, and histology of corneal flap cuts using a 200-kHz femtosecond laser
Verf.angabe:Ramin Khoramnia, Josefina P. Salgado, Chris P. Lohmann, Karin A. Kobuch, Christoph Winkler von Mohrenfels
Jahr:2012
Jahr des Originals:2011
Umfang:7 S.
Fussnoten:Article first published online: May 26, 2011 ; Gesehen am 22.08.2018
Titel Quelle:Enthalten in: European journal of ophthalmology
Ort Quelle:Thousand Oaks, CA : Sage Publishing, 1991
Jahr Quelle:2012
Band/Heft Quelle:22(2012), 2, Seite 161-167
ISSN Quelle:1724-6016
Abstract:PurposeLaser-assisted in situ keratomileusis (LASIK) requires precise corneal flap cutting. Especially the creation of thin flaps has recently gained importance for thin-flap LASIK. Currently, there is a trend towards faster femtosecond lasers that can produce flaps in a short period of time. We analyzed flaps created with a 200-kHz femtosecond laser concerning their cut precision, morphology, and histology.MethodsFemtosecond laser flap cutting was performed on 36 porcine cadaver eyes using the prototype 200-kHz femtosecond laser UltraFlap (WaveLight GmbH, Erlangen, Germany). The eyes were assigned to 3 thickness groups, with a cut depth of 100 µm, 130 µm, or 180 µm, respectively. Additionally, flap diameters were varied, ranging from 8.0 mm to 9.5 mm. Flap thicknesses were determined with a micrometer gauge. Flap diameters were measured with a sliding caliper. Furthermore, flaps were created for histologic examination.ResultsThere were no complications during flap creation. The mean flap thickness and standard deviation was (in micrometers) 96.33±7.45 (intended thickness: 100), 134.67±4.96 (intended thickness: 130), and 174.59±9.35 (intended thickness: 180), respectively. The flap diameter revealed a mean (in mm) of 8.03±0.15 (intended diameter: 8.0), 8.56±0.10 (intended diameter: 8.5), 9.09±0.10 (intended diameter: 9.0), and 9.54±0.15 (intended diameter: 9.5), respectively. Histologic examination showed very little to almost no changes in the structure of the corneal stroma.ConclusionsFlap creation could be performed easily without any complications. The morphology and accuracy of the cuts were very reliable and precise. Histology showed a smooth cut.
DOI:doi:10.5301/EJO.2011.8376
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.5301/EJO.2011.8376
 Volltext: https://doi.org/10.5301/EJO.2011.8376
 DOI: https://doi.org/10.5301/EJO.2011.8376