Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Zapp, Jascha [VerfasserIn]   i
 Domsch, Sebastian [VerfasserIn]   i
 Weingärtner, Sebastian [VerfasserIn]   i
 Schad, Lothar R. [VerfasserIn]   i
Titel:Gaussian signal relaxation around spin echoes
Titelzusatz:implications for precise reversible transverse relaxation quantification of pulmonary tissue at 1.5 and 3 Tesla
Verf.angabe:Jascha Zapp, Sebastian Domsch, Sebastian Weingärtner, and Lothar R. Schad
Jahr des Originals:2016
Umfang:8 S.
Fussnoten:Published online 25 June 2016 ; Gesehen am 22.08.2018
Titel Quelle:Enthalten in: Magnetic resonance in medicine
Jahr Quelle:2017
Band/Heft Quelle:77(2017), 5, S. 1938-1945
ISSN Quelle:1522-2594
Abstract:Purpose To characterize the reversible transverse relaxation in pulmonary tissue and to study the benefit of a quadratic exponential (Gaussian) model over the commonly used linear exponential model for increased quantification precision. Methods A point-resolved spectroscopy sequence was used for comprehensive sampling of the relaxation around spin echoes. Measurements were performed in an ex vivo tissue sample and in healthy volunteers at 1.5 Tesla (T) and 3 T. The goodness of fit using and the precision of the fitted relaxation time by means of its confidence interval were compared between the two relaxation models. Results The Gaussian model provides enhanced descriptions of pulmonary relaxation with lower by average factors of 4 ex vivo and 3 in volunteers. The Gaussian model indicates higher sensitivity to tissue structure alteration with increased precision of reversible transverse relaxation time measurements also by average factors of 4 ex vivo and 3 in volunteers. The mean relaxation times of the Gaussian model in volunteers are = (1.97 ± 0.27) msec at 1.5 T and = (0.83 ± 0.21) msec at 3 T. Conclusion Pulmonary signal relaxation was found to be accurately modeled as Gaussian, providing a potential biomarker with high sensitivity. Magn Reson Med 77:1938-1945, 2017. © 2016 International Society for Magnetic Resonance in Medicine
DOI:doi:10.1002/mrm.26280
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Verlag: http://dx.doi.org/10.1002/mrm.26280
 Verlag: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.26280
 DOI: https://doi.org/10.1002/mrm.26280
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1580298532
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68297972   QR-Code
zum Seitenanfang