| Online-Ressource |
Verfasst von: | Jürchott, Alexander [VerfasserIn]  |
| Saleem, Muhammad Abdullah [VerfasserIn]  |
| Hilgenfeld, Tim [VerfasserIn]  |
| Freudlsperger, Christian [VerfasserIn]  |
| Zingler, Sebastian [VerfasserIn]  |
| Lux, Christopher J. [VerfasserIn]  |
| Bendszus, Martin [VerfasserIn]  |
| Heiland, Sabine [VerfasserIn]  |
Titel: | 3D cephalometric analysis using Magnetic Resonance Imaging |
Titelzusatz: | validation of accuracy and reproducibility |
Verf.angabe: | Alexander Juerchott, Muhammad Abdullah Saleem, Tim Hilgenfeld, Christian Freudlsperger, Sebastian Zingler, Christopher J. Lux, Martin Bendszus & Sabine Heiland |
E-Jahr: | 2018 |
Jahr: | 29 August 2018 |
Umfang: | 11 S. |
Fussnoten: | Gesehen am 20.09.2018 |
Titel Quelle: | Enthalten in: Scientific reports |
Ort Quelle: | [London] : Macmillan Publishers Limited, part of Springer Nature, 2011 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 8(2018) Artikel-Nummer 13029, 11 Seiten |
ISSN Quelle: | 2045-2322 |
Abstract: | The aim of this study was to validate geometric accuracy and in vivo reproducibility of landmark-based cephalometric measurements using high-resolution 3D Magnetic Resonance Imaging (MRI) at 3 Tesla. For accuracy validation, 96 angular and 96 linear measurements were taken on a phantom in 3 different positions. In vivo MRI scans were performed on 3 volunteers in five head positions. For each in vivo scan, 27 landmarks were determined from which 19 angles and 26 distances were calculated. Statistical analysis was performed using Bland-Altman analysis, the two one-sided tests procedure and repeated measures one-way analysis of variance. In comparison to ground truth, all MRI-based phantom measurements showed statistical equivalence (p 0.05). Ranges between maximum and minimum in vivo values were consistently smaller than 2° and 2 mm, respectively (average ranges: 0.88°/0.87 mm). In conclusion, this study demonstrates that accurate and reproducible 3D cephalometric analysis can be performed without exposure to ionizing radiation using MRI. |
DOI: | doi:10.1038/s41598-018-31384-8 |
URL: | kostenfrei: Volltext: http://dx.doi.org/10.1038/s41598-018-31384-8 |
| kostenfrei: Volltext: https://www.nature.com/articles/s41598-018-31384-8 |
| DOI: https://doi.org/10.1038/s41598-018-31384-8 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1581138407 |
Verknüpfungen: | → Zeitschrift |
|
|
| |
Lokale URL UB: | Zum Volltext |
3D cephalometric analysis using Magnetic Resonance Imaging / Jürchott, Alexander [VerfasserIn]; 29 August 2018 (Online-Ressource)