Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Smakic, Arman [VerfasserIn]   i
 Rathmann, Nils-Andreas [VerfasserIn]   i
 Kostrzewa, Michael [VerfasserIn]   i
 Schönberg, Stefan [VerfasserIn]   i
 Weiß, Christel [VerfasserIn]   i
 Diehl, Steffen J. [VerfasserIn]   i
Titel:Performance of a robotic assistance device in computed tomography-guided percutaneous diagnostic and therapeutic procedures
Verf.angabe:Arman Smakic, Nils Rathmann, Michael Kostrzewa, Stefan O. Schönberg, Christel Weiß, Steffen J. Diehl
Jahr:2018
Jahr des Originals:2017
Umfang:6 S.
Teil:volume:41
 year:2018
 number:4
 pages:639-644
 extent:6
Fussnoten:First online: 20 November 2017 ; Gesehen am 25.09.2018
Titel Quelle:Enthalten in: CardioVascular and interventional radiology
Ort Quelle:Berlin : Springer, 1978
Jahr Quelle:2018
Band/Heft Quelle:41(2018), 4, Seite 639-644
ISSN Quelle:1432-086X
Abstract:PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.
DOI:doi:10.1007/s00270-017-1841-8
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1007/s00270-017-1841-8
 Volltext: https://doi.org/10.1007/s00270-017-1841-8
 DOI: https://doi.org/10.1007/s00270-017-1841-8
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:CT-guided interventions
 Intervention time
 Precision
 Radiation
 Robotic assistance
K10plus-PPN:1581265727
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68308795   QR-Code
zum Seitenanfang