Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Stuck, Boris [VerfasserIn]   i
 Leitzbach, Sarah [VerfasserIn]   i
 Maurer, Joachim T. [VerfasserIn]   i
Titel:Effects of continuous positive airway pressure on apnea-hypopnea index in obstructive sleep apnea based on long-term compliance
Verf.angabe:Boris A. Stuck, Sarah Leitzbach, Joachim T. Maurer
Jahr:2012
Umfang:5 S.
Fussnoten:Article was published online on 19 May 2011 ; Gesehen am 12.10.2018
Titel Quelle:Enthalten in: Sleep and breathing
Ort Quelle:Berlin : Springer, 1996
Jahr Quelle:2012
Band/Heft Quelle:16(2012), 2, Seite 467-471
ISSN Quelle:1522-1709
Abstract:Purpose: Although continuous positive airway pressure (CPAP) is the gold standard in the treatment of obstructive sleep apnea (OSA), its effectiveness depends on the regular use. In this retrospective study, the effectiveness of CPAP with regard to the reduction of the apnea-hypopnea index was calculated based on individual adherence data extracted from a cohort of patients with OSA - Methods: The electronic database was analyzed for follow-up visits of patients receiving CPAP for OSA. The following information was extracted the charts of 750 patients: apnea-hypopnea index (AHI) at diagnosis, AHI with CPAP, duration of therapy, hours of CPAP use, and subjective hours of sleep. Eighty-two successfully treated and stable CPAP patients (AHI/Epworth Sleepiness Scale (ESS) at baseline 35.6 ± 22.1/10.5 ± 5.1) could be further evaluated. Results: Mean AHI under CPAP was 2.4 ± 2.5 with an ESS of 6.9 ± 4.2. Subjective hours of sleep were 6.5 ± 1.1. The average treatment period was 584.6 ± 566.5 days (3,800 h of sleep). Mean hours of use was 2,712 ± 3,234 (4.69 ± 2.42 per night). This leads to the following calculated measures: hours of sleep without CPAP, 1,088; number of respiratory events with CPAP, 6508.8; number of respiratory events without CPAP, 38,732.8; total number or respiratory events, 45,241.6; average AHI, 11.91.Conclusions: Even in an ideal group of patients, CPAP cannot eliminate respiratory events due to limited adherence. Adherence needs to be taken into account when comparing the effects of CPAP on the AHI with alternative treatment methods, especially those with 100% adherence (e.g., surgery).
DOI:doi:10.1007/s11325-011-0527-8
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1007/s11325-011-0527-8
 Volltext: https://doi.org/10.1007/s11325-011-0527-8
 DOI: https://doi.org/10.1007/s11325-011-0527-8
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Adherence
 Apnea-hypopnea index
 Compliance
 Continuous positive airway pressure
 Obstructive sleep apnea
K10plus-PPN:1581870566
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68314836   QR-Code
zum Seitenanfang