Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Doizi, Steeve [VerfasserIn]   i
 Knoll, Thomas [VerfasserIn]   i
Titel:First clinical evaluation of a new single-use flexible ureteroscope (LithoVue)
Titelzusatz:a European prospective multicentric feasibility study
Verf.angabe:Steeve Doizi, Guido Kamphuis, Guido Giusti, Kim Hovgaard Andreassen, Thomas Knoll, Palle Jörn Osther, Cesare Scoffone, Daniel Pérez-Fentes, Silvia Proietti, Oliver Wiseman, Jean de la Rosette, Olivier Traxer
E-Jahr:2017
Jahr:May 2017
Jahr des Originals:2016
Umfang:10 S.
Fussnoten:Gesehen am 17.10.2018 ; Published online: 26 September 2016
Titel Quelle:Enthalten in: World journal of urology
Ort Quelle:Berlin : Springer, 1983
Jahr Quelle:2017
Band/Heft Quelle:35(2017), 5, Seite 809-818
ISSN Quelle:1433-8726
Abstract:Introduction: We evaluated a new digital single-use flexible ureteroscope, LithoVue with respect to deflection, image quality and maneuverability. Methods: A prospective cohort study was conducted in eight tertiary reference centers in Europe in December 2015 and January 2016. All consecutive patients included underwent flexible ureteroscopy and were 18 years or older. Deflection and image quality pre- and post-use and maneuverability were rated with a Likert scale. Results: A total of 40 procedures were performed (five per institution). The indication for FURS was treatment of renal stones in 92.5 % of the cases. Before LithoVue usage, the median measured upward and downward deflections were both 270°. Image quality was rated as “very good” in 65 % of cases and “good” in 30 %. Maneuverability was “very good” in 77.5 % and “good” in 17.5 %. At the final evaluation, median upward and downward deflections were both 270°. Image quality was still “very good” in 65 % of cases and “good” in 30 % with no significant difference compared with preoperative data (p = 1). Maneuverability was “very good” in 72.5 % and “good” in 17.5 %, with no significant difference compared with preoperative data (p = 0.92). Two LithoVue broke during surgery (5 %): one occurring in extreme deflection with acute infundibulopelvic angle and spontaneous loss of vision for the second one. Conclusion: The LithoVue displayed good image quality, active deflection and maneuverability. Further evaluation of surgical outcomes and cost analysis will help to present the best utility of this single-use FURS in current practice.
DOI:doi:10.1007/s00345-016-1936-x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1007/s00345-016-1936-x
 Volltext: https://doi.org/10.1007/s00345-016-1936-x
 DOI: https://doi.org/10.1007/s00345-016-1936-x
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Digital flexible ureteroscope
 Disposable
 Flexible ureteroscopy
 Single use
K10plus-PPN:1582036039
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68318051   QR-Code
zum Seitenanfang