Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Rank, Christopher M. [VerfasserIn]   i
 Buzan, Maria Teodora [VerfasserIn]   i
 Dinkel, Julien [VerfasserIn]   i
Titel:4D respiratory motion-compensated image reconstruction of free-breathing radial MR data with very high undersampling
Verf.angabe:Christopher M. Rank, Thorsten Heußer, Maria T.A. Buzan, Andreas Wetscherek, Martin T. Freitag, Julien Dinkel, and Marc Kachelrieß
Jahr:2017
Jahr des Originals:2016
Umfang:14 S.
Teil:volume:77
 year:2017
 number:3
 pages:1170-1183
 extent:14
Fussnoten:Published online 16 March 2016 ; Gesehen am 19.10.2018
Titel Quelle:Enthalten in: Magnetic resonance in medicine
Ort Quelle:New York, NY [u.a.] : Wiley-Liss, 1984
Jahr Quelle:2017
Band/Heft Quelle:77(2017), 3, Seite 1170-1183
ISSN Quelle:1522-2594
Abstract:Purpose To develop four-dimensional (4D) respiratory time-resolved MRI based on free-breathing acquisition of radial MR data with very high undersampling. Methods We propose the 4D joint motion-compensated high-dimensional total variation (4D joint MoCo-HDTV) algorithm, which alternates between motion-compensated image reconstruction and artifact-robust motion estimation at multiple resolution levels. The algorithm is applied to radial MR data of the thorax and upper abdomen of 12 free-breathing subjects with acquisition times between 37 and 41 s and undersampling factors of 16.8. Resulting images are compared with compressed sensing-based 4D motion-adaptive spatio-temporal regularization (MASTeR) and 4D high-dimensional total variation (HDTV) reconstructions. Results For all subjects, 4D joint MoCo-HDTV achieves higher similarity in terms of normalized mutual information and cross-correlation than 4D MASTeR and 4D HDTV when compared with reference 4D gated gridding reconstructions with 8.4 ± 1.1 times longer acquisition times. In a qualitative assessment of artifact level and image sharpness by two radiologists, 4D joint MoCo-HDTV reveals higher scores (P < 0.05) than 4D HDTV and 4D MASTeR at the same undersampling factor and the reference 4D gated gridding reconstructions, respectively. Conclusions 4D joint MoCo-HDTV enables time-resolved image reconstruction of free-breathing radial MR data with undersampling factors of 16.8 while achieving low-streak artifact levels and high image sharpness. Magn Reson Med 77:1170-1183, 2017. © 2016 International Society for Magnetic Resonance in Medicine
DOI:doi:10.1002/mrm.26206
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: http://dx.doi.org/10.1002/mrm.26206
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mrm.26206
 DOI: https://doi.org/10.1002/mrm.26206
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:4D MRI
 joint estimation
 radial sampling
 respiratory motion compensation
 undersampling
K10plus-PPN:1582124884
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68319088   QR-Code
zum Seitenanfang