Titel:Extracranial stereotactic radiation therapy
Titelzusatz:set-up accuracy of patients treated for liver metastases
Verf.angabe:K.K. Herfarth, J. Debus, F. Lohr, M.L. Bahner, P. Fritz, A. Höss, W. Schlegel, and M.F. Wannenmacher
E-Jahr:2000
Jahr:27 January 2000
Umfang:7 S.
Fussnoten:Gesehen am 19.02.2019
Titel Quelle:Enthalten in: International journal of radiation oncology, biology, physics
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1975
Jahr Quelle:2000
Band/Heft Quelle:46(2000), 2, Seite 329-335
ISSN Quelle:1879-355X
Abstract:Purpose: Patients with liver metastases might benefit from high-dose conformal radiation therapy. A high accuracy of repositioning and a reduction of target movement are necessary for such an approach. The set-up accuracy of patients with liver metastases treated with stereotactic single dose radiation was evaluated. Methods and Materials: Twenty-four patients with liver metastases were treated with single dose radiation therapy on 26 occasions using a self-developed stereotactic frame. Liver movement was reduced by abdominal pressure. The effectiveness was evaluated under fluoroscopy. CT scans were performed on the planning day and directly before treatment. Representative reference marks were chosen and the coordinates were calculated. In addition, the target displacement was quantitatively evaluated after treatment. Results: Diaphragmal movement was reduced to median 7 mm (range: 3-13 mm). The final set-up accuracy of the body was limited to all of median 1.8 mm in latero-lateral direction (range: 0.3-5.0 mm) and 2.0 mm in anterior-posterior direction (0.8-3.8 mm). Deviations of the body in cranio-caudal direction were always less than the thickness of one CT slice (<5 mm). However, a repositioning was necessary in 16 occasions. The final target shift was median 1.6 mm (0.2-7.0 mm) in latero-lateral and 2.3 mm in anterior-posterior direction (0.0-6.3 mm). The median shift in cranio-caudal direction was 4.4 mm (0.0-10.0 mm). Conclusions: In patients with liver metastases, a high set-up accuracy of the body and the target can be achieved. This allows a high-dose focal radiotherapy of these lesions. However, a control CT scan should be performed directly before therapy to confirm set-up accuracy and possibly prompt necessary corrections.
DOI:doi:10.1016/S0360-3016(99)00413-7
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1016/S0360-3016(99)00413-7
 Volltext: http://www.sciencedirect.com/science/article/pii/S0360301699004137
 DOI: https://doi.org/10.1016/S0360-3016(99)00413-7
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Conformal therapy
 Liver
 Set-up
K10plus-PPN:1587780038
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68360076   QR-Code
zum Seitenanfang