Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Warschkow, René [VerfasserIn]   i
 Tarantino, Ignazio [VerfasserIn]   i
 Ukegjini, Kristjan [VerfasserIn]   i
Titel:Diagnostic study and meta-analysis of C-reactive protein as a predictor of postoperative inflammatory complications after gastroesophageal cancer surgery
Verf.angabe:Rene Warschkow, Ignazio Tarantino, Kristjan Ukegjini, Ulrich Beutner, Sascha A. Müller, Bruno M. Schmied, Thomas Steffen
E-Jahr:2012
Jahr:08 March 2012
Umfang:10 S.
Fussnoten:Gesehen am 05.03.2019
Titel Quelle:Enthalten in: Langenbeck's archives of surgery
Ort Quelle:Berlin : Springer, 1948
Jahr Quelle:2012
Band/Heft Quelle:397(2012), 5, Seite 727-736
ISSN Quelle:1435-2451
Abstract:PurposeThis study assessed the diagnostic accuracy of C-reactive protein (CRP) after gastroesophageal cancer resection for postoperative inflammatory complications (PIC).MethodsThe clinical data and CRP values of patients operated on for gastroesophageal cancer surgery between 1997 and 2009 were retrospectively analyzed. The results of this study were compared with published data using a meta-analytic approach for diagnostic outcomes.ResultsOf 210 patients included in the study, 59 developed PIC (28.1 %; 95 % CI: 22.5-34.5 %). On the postoperative day (POD) 4 and 7, CRP had the best diagnostic accuracy for PIC (AUC 0.77; 95 % CI, 0.64-0.91, AUC 0.81; 95 % CI, 0.71-0.91). Using a cut-off value of 141 mg/L (95 % CI, 131-278 mg/L) for CRP on POD 4, the sensitivity was 0.78 (95 % CI, 0.55-0.91), the specificity was 0.70 (95 % CI, 0.53-0.83) and the NPV was 0.89 (95 % CI, 0.77-0.95). The in-hospital mortality rate was 3.3 % (95 % CI, 1.5-6.9 %). In a diagnostic meta-analysis that included two additional studies, CRP had a significant predictive value after POD 3.ConclusionThere is limited evidence for the diagnostic accuracy of CRP levels for PIC after gastroesophageal cancer surgery. CRP levels on POD 4 might be useful to rule out PIC, but its diagnostic accuracy is moderate at best. For clinical routine use CRP levels are clearly not sufficient to predict PIC and have to be interpreted in the context of the whole clinical picture.
DOI:doi:10.1007/s00423-012-0944-6
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1007/s00423-012-0944-6
 Volltext: https://doi.org/10.1007/s00423-012-0944-6
 DOI: https://doi.org/10.1007/s00423-012-0944-6
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:C-reactive protein
 Diagnostic study
 Gastroesophageal cancer
 Postoperative inflammatory complications
K10plus-PPN:1588338142
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68365744   QR-Code
zum Seitenanfang