Titel:Imaging artifacts of Onyx and PHIL on conventional CT, cone-beam CT and MRI in an animal model
Verf.angabe:Dominik F. Vollherbst, Ruth Otto, Thuy Do, Hans U. Kauczor, Martin Bendszus, Christof M. Sommer, Markus A. Möhlenbruch
E-Jahr:2018
Jahr:July 4, 2018
Umfang:8 S.
Fussnoten:Gesehen am 29.03.2019
Titel Quelle:Enthalten in: Interventional neuroradiology
Ort Quelle:London : Sage Publishing, 1995
Jahr Quelle:2018
Band/Heft Quelle:24(2018), 6, Seite 693-701
ISSN Quelle:2385-2011
Abstract:Background and purposeA frequently reported drawback of ethylene vinyl alcohol copolymer-based liquid embolic agents is the production of artifacts in diagnostic imaging. New embolic agents, such as Precipitating hydrophobic injectable liquid (PHIL; MicroVention, Tustin, CA, USA), are supposed to induce significantly fewer artifacts. The purpose of this study is to assess the degree of artifacts induced by the liquid embolic agents Onyx (Medtronic Neurovascular, Irvine, CA, USA) and PHIL in conventional computed tomography (CT), cone-beam CT and magnetic resonance imaging (MRI) in an experimental in vivo model.Materials and methodsIn 10 pigs the rete mirabile was embolized with Onyx (n?=?5) or PHIL (n?=?5). After embolization, conventional CT, cone-beam CT and MRI were performed. The degree of artifacts was graded qualitatively (five-point scale; for CT and MRI) and quantitatively (HUs of well-defined regions of interest (ROIs); for CT only).ResultsArtifacts were significantly more severe for Onyx both in the qualitative (e.g. conventional CT: 2 versus 5 (medians); p?=?0.008) and in the quantitative image analysis (e.g. cone-beam CT: standard deviation of a ROI near to the embolic agent cast, 94 HU versus 38 HU (medians); p?=?0.008). Neither Onyx nor PHIL produced any apparent artifacts in MRI.ConclusionPHIL produces fewer artifacts than Onyx in conventional CT and cone-beam CT in an experimental in vivo model.
DOI:doi:10.1177/1591019918782692
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1177/1591019918782692
 DOI: https://doi.org/10.1177/1591019918782692
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1662540221
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68374093   QR-Code
zum Seitenanfang