Verfasst von:Kaireit, Till Frederik [VerfasserIn]   i
 Jobst, Bertram [VerfasserIn]   i
 Kauczor, Hans-Ulrich [VerfasserIn]   i
Titel:Comparison of quantitative regional perfusion-weighted phase resolved functional lung (PREFUL) MRI with dynamic gadolinium-enhanced regional pulmonary perfusion MRI in COPD patients
Verf.angabe:Till F. Kaireit, Andreas Voskrebenzev, Marcel Gutberlet, Julia Freise, Bertram Jobst, Hans-Ulrich Kauczor, Tobias Welte, Frank Wacker, and Jens Vogel‐Claussen
Jahr:2019
Jahr des Originals:2018
Umfang:11 S.
Fussnoten:First published: 22 October 2018 ; Gesehen am 05.04.2019
Titel Quelle:Enthalten in: Journal of magnetic resonance imaging
Ort Quelle:New York, NY : Wiley-Liss, 1991
Jahr Quelle:2019
Band/Heft Quelle:49(2019), 4, Seite 1122-1132
ISSN Quelle:1522-2586
Abstract:Background Perfusion-weighted noncontrast-enhanced proton lung MRI during free breathing is maturing as a novel technique for assessment of regional lung perfusion, but has not yet been validated in chronic obstructive pulmonary disease (COPD) patients. Purpose To compare pulmonary parenchymal perfusion assessed by noncontrast-enhanced perfusion-weighted phase-resolved functional lung (PREFUL)-MRI with lung perfusion determined with dynamic gadolinium-enhanced (DCE)-MRI and with lung function test parameters. Study Type Prospective. Population A single-center subset of the COPD cohort 'COPD and SYstemic consequenzes-COmorbidities NETwork' (COSYCONET). Forty-seven patients with COPD (median age 66 [57-70] years) were studied. Field Strength/Sequence For PREFUL-MRI a spoiled gradient echo sequence and for DCE-MRI, a 3D time-resolved spoiled gradient echo sequence was used at 1.5T. Assessment PREFUL-MRI coronal slices were acquired in free breathing. DCE-MRI was performed in breath-hold with administration of 0.025 mmol/kg bodyweight of gadobutrol i.v. at a rate of 4 ml/s and pulmonary blood flow (PBF) maps were calculated. Slices of PREFUL and DCE-MRI were matched by their ventrodorsal position and corresponding slices were coregistered for evaluation. Perfusion defect percentages (QDP) were calculated for both methods. Statistical Tests The obtained parameters were correlated using Spearman's correlation coefficient (r) and Bland-Altman plot analysis. Results PREFUL-QDP showed an absolute and spatial agreement with PBF-QDP on a global (39.3 (31.8-45.5)% vs. 44.7 (35.4-50.0)% with a spatial overlap of 62.2 (57.2-67.2)%)) as well as on a lobar level and correlated with lung function test parameters (PREFUL-QDP vs. FEV1, r = -0.75, P < 0.0001). There was a systematic overestimation of PREFUL-QDP compared with PBF-QDP, mainly in the lower lobes, resulting in an overall overestimation for the whole lung with a mean difference of 5% (95% confidence interval [CI]: 3.0%; 7.0%; STD 6.8%). Data Conclusion PREFUL-MRI is a promising noninvasive, radiation-free tool for quantification of regional perfusion in COPD patients. Level of Evidence: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1122-1132.
DOI:doi:10.1002/jmri.26342
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1002/jmri.26342
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26342
 DOI: https://doi.org/10.1002/jmri.26342
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:COPD
 DCE
 Fourier decomposition
 free breathing
 lung function tests
 PBF
 PREFUL
K10plus-PPN:1662866607