Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Gillissen, Adrian [VerfasserIn]   i
 Herth, Felix [VerfasserIn]   i
Titel:Patient satisfaction and clinical outcomes with budesonide plus formoterol spiromax for asthma and chronic obstructive pulmonary disease
Titelzusatz:a real-world, observational trial
Verf.angabe:Adrian Gillissen, Christian Gessner, Klaus Hechenbichler, Felix J.F. Herth, Ralf Juenemann, Frank Kanniess, Peter Kardos, Marek Lommatzsch, Regina Schneidereit, Wolfram Windisch
Jahr:2019
Jahr des Originals:2018
Umfang:10 S.
Teil:volume:97
 year:2019
 number:4
 pages:292-301
 extent:10
Fussnoten:Online first articles ; Gesehen am 08.04.2019
Titel Quelle:Enthalten in: Respiration
Ort Quelle:Basel : Karger, 1944
Jahr Quelle:2019
Band/Heft Quelle:97(2019), 4, Seite 292-301
ISSN Quelle:1423-0356
Abstract:Background: The fixed-dose combination of budesonide/formoterol (B/F) has been available in the Spiromax® dry powder inhaler since 2014. Objectives: To assess patient satisfaction, inhaler use errors, and disease control in patients with asthma or chronic obstructive pulmonary disease (COPD) treated with B/F Spiromax. Methods: This non-interventional, prospective, 12-week study enrolled consecutive asthma or COPD patients who had recently begun treatment with B/F Spiromax or were switched from another inhaled corticosteroid/long-acting β 2-agonist combination to B/F Spiromax in routine clinical practice. Patients recruited from 243 specialist respiratory clinics or general practices in Germany were assessed for patient satisfaction (Satisfaction with Inhalers and Preference questionnaire), inhaler application errors (modified Easy Low Instruction over Time checklist), disease control, and safety. Results: The population included 3,943 patients: asthma n = 2,707 (68.7%); COPD n = 1,236 (31.3%). At baseline, 60.1% of patients were “satisfied” or “very satisfied” with their previous inhaler, and this increased to 88.8% at week 12 of B/F Spiromax use. Overall, 62.1% of pre-treated patients preferred B/F Spiromax to their old inhaler. The frequency of any handling error observed with B/F Spiromax at week 12 was lower than at baseline (11.9 vs. 25.5% of patients, respectively). After 12 weeks, 77.4% were assessed as having improved (minimally, much, or very much) overall health status versus baseline. Guideline-defined disease severity (as rated by physicians) and patient-reported symptom severity improved during the study in both asthma and COPD patients. B/F Spiromax was well tolerated. Conclusion: B/F Spiromax was associated with high patient satisfaction, low device handling error rate, and improvements in clinical outcomes in real-world clinical practice.
DOI:doi:10.1159/000493860
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1159/000493860
 Volltext: https://www.karger.com/Article/FullText/493860
 DOI: https://doi.org/10.1159/000493860
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1662948840
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68378849   QR-Code
zum Seitenanfang