| Online-Ressource |
Verfasst von: | Eberhard, Lydia [VerfasserIn]  |
| Schindler, Hans J. [VerfasserIn]  |
| Hellmann, Daniel [VerfasserIn]  |
| Schmitter, Marc [VerfasserIn]  |
| Rammelsberg, Peter [VerfasserIn]  |
| Giannakopoulos, Nikolaos Nikitas [VerfasserIn]  |
Titel: | Comparison of particle-size distributions determined by optical scanning and by sieving in the assessment of masticatory performance |
Verf.angabe: | L. Eberhard, H.J. Schindler, D. Hellmann, M. Schmitter, P. Rammelsberg & N.N. Giannakopoulos |
E-Jahr: | 2012 |
Jahr: | 06 January 2012 |
Umfang: | 11 S. |
Fussnoten: | Gesehen am 15.04.2019 |
Titel Quelle: | Enthalten in: Journal of oral rehabilitation |
Ort Quelle: | Oxford [u.a.] : Wiley-Blackwell, 1974 |
Jahr Quelle: | 2012 |
Band/Heft Quelle: | 39(2012), 5, Seite 338-348 |
ISSN Quelle: | 1365-2842 |
Abstract: | Aim of this study was to introduce a feasible and valid technique for the assessment of masticatory performance that is comparable to the standard sieving method. Twenty-one chewing samples (Optosil) comminuted by healthy dentate adults were analysed with a sieving and scanning method. Scanning was performed using a conventional flatbed scanner (1200 dpi). All scanned images underwent image analysis (ImageJ), which yielded descriptive parameters such as area, best-fitting ellipse for each particle. Of the 2D-image, a volume was estimated for each particle, which was converted into a weight. To receive a discrete distribution of particle sizes comparable to sieving, five chewing samples were used to calculate a size-dependent area-volume-conversion factor. The sieving procedure was carried out with a stack of 10 sieves, and the retained particles per sieve were weighed. The cumulated weights yielded by either method were curve-fitted with the Rosin-Rammler distribution to determine the median particle size x50. The Rosin-Rammler distributions for sieving and scanning resemble each other. The distributions show a high correlation (0·919-1·0, n = 21, P < 0·01, Pearson’s correlation coefficient). The median particle sizes vary between 3·83 and 4·77 mm (mean: 4·31) for scanning and 3·53 and 4·55 mm (mean: 4·21) for sieving. On average, scanning overestimates the x50 values by 2·4%. A modified Bland-Altman plot reveals that 95% of the x50 values fall within 10% of the average x50. The scanning method is a valid, simple and feasible method to determine masticatory performance. |
DOI: | doi:10.1111/j.1365-2842.2011.02275.x |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext ; Verlag ; Resolving-System: https://doi.org/10.1111/j.1365-2842.2011.02275.x |
| Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1365-2842.2011.02275.x |
| DOI: https://doi.org/10.1111/j.1365-2842.2011.02275.x |
Datenträger: | Online-Ressource |
Sprache: | eng |
Sach-SW: | mastication |
| masticatory performance |
| optosil |
| scanning |
| sieving |
K10plus-PPN: | 1663255539 |
Verknüpfungen: | → Zeitschrift |
Comparison of particle-size distributions determined by optical scanning and by sieving in the assessment of masticatory performance / Eberhard, Lydia [VerfasserIn]; 06 January 2012 (Online-Ressource)