Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Rubin, Tom [VerfasserIn]   i
 Polychronidis, Georgios [VerfasserIn]   i
Titel:Kinetic validation of the LiMAx test during 10 000 intravenous 13C-methacetin breath tests
Verf.angabe:Tom Moses Rubin, Karsten Heyne, Axel Luchterhand, Jan Bednarsch, Florian W. R. Vondran, Georgios Polychronidis, Maciej Malinowski, Alen Nikolic, Hans-Michael Tautenhahn, Maximilian Jara, Tilo Wünsch, Martin Stockmann and Johan Friso Lock
Jahr:2018
Jahr des Originals:2017
Fussnoten:Published 28 November 2017 ; Gesehen am 24.04.2019 ; Im Titel ist "13" in 13C-methacetin hochgestellt
Titel Quelle:Enthalten in: Journal of breath research
Ort Quelle:Bristol : IOP, 2007
Jahr Quelle:2018
Band/Heft Quelle:12(2018,1) Artikel-Nummer 016005
ISSN Quelle:1752-7163
Abstract:The maximal liver function capacity (LiMAx) test, a novel 13C-methacetin breath test, has proven clinical validity in determining hepatic metabolic capacity. In contrast to prior 13C-methacetin breath test protocols, the LiMAx test is performed by intravenous body-weight-adjusted substrate administration. Furthermore, the DOB kinetics (delta over baseline of the time-dependent exhaled 13CO2/12CO2 ratio) are measured online at the bedside with a high time resolution in order to determine the maximum DOB. The aim of this study was to analyze the recorded DOB kinetics in a large population for further refinement of the test protocol. Two new methods of kinetic analysis are proposed in this article: the time dependency of the DOB kinetics and the time interval until half of the DOB maximum. A total of 10 100 LiMAx tests on 8483 patients performed during routine clinics at eight centers were available. The kinetic analysis revealed a specific pattern of DOB kinetics depending upon LiMAx result. In addition, potential co-factors for DOB kinetics, such as weight, height, gender and age, were analyzed, yielding a potential influence of gender and smoking behavior. Both the specific patterns and the proposed kinetic analysis have the potential to further improve the sensitivity and specificity of the test and its clinical applicability by shortening its duration.
DOI:doi:10.1088/1752-7163/aa820b
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1088/1752-7163/aa820b
 Volltext: https://doi.org/10.1088%2F1752-7163%2Faa820b
 DOI: https://doi.org/10.1088/1752-7163/aa820b
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1663538964
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68382174   QR-Code
zum Seitenanfang