Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
Verfasst von:Prall, Matthias [VerfasserIn]   i
 Lehmann, H. Immo [VerfasserIn]   i
 Prokesch, Hannah [VerfasserIn]   i
 Richter, Daniel [VerfasserIn]   i
 Graeff, Christian [VerfasserIn]   i
 Kaderka, Robert [VerfasserIn]   i
 Sonnenberg, Karin [VerfasserIn]   i
 Hauswald, Henrik [VerfasserIn]   i
 Weymann, Alexander [VerfasserIn]   i
 Bauer, Julia [VerfasserIn]   i
 Constantinescu, Anna [VerfasserIn]   i
 Haberer, Thomas [VerfasserIn]   i
 Debus, Jürgen [VerfasserIn]   i
 Szabó, Gábor [VerfasserIn]   i
 Korkmaz-İçöz, Sevil [VerfasserIn]   i
 Durante, Marco [VerfasserIn]   i
 Packer, Douglas L. [VerfasserIn]   i
 Bert, Christoph [VerfasserIn]   i
Titel:Treatment of arrhythmias by external charged particle beams
Titelzusatz:a Langendorff feasibility study
Verf.angabe:Matthias Prall, H. Immo Lehmann, Hannah Prokesch, Daniel Richter, Christian Graeff, Robert Kaderka, Karin Sonnenberg, Henrik Hauswald, Alexander Weymann, Julia Bauer, Anna Constantinescu, Thomas Haberer, Jürgen Debus, Gábor Szabó, Sevil Korkmaz, Marco Durante, Douglas L. Packer and Christoph Bert
Jahr:2015
Titel Quelle:Enthalten in: Biomedical engineering
Ort Quelle:Berlin [u.a.] : de Gruyter, 1971
Jahr Quelle:2015
Band/Heft Quelle:60(2015), 2, Seite 147-156
ISSN Quelle:0013-5585
Abstract:Hadron therapy has already proven to be sucessful in cancer therapy, and might be a noninvasive alternative for the ablation of cardiac arrhythmias in humans. We present a pilot experiment investigating acute effects of a 12C irradiation on the AV nodes of porcine hearts in a Langendorff setup. This setup was adapted to the requirements of charged particle therapy. Treatment plans were computed on calibrated CTs of the hearts. Irradiation was applied in units of 5 and 10 Gy over a period of about 3 h until a total dose of up to 160 Gy was reached. Repeated application of the same irradiation field helped to mitigate motion artifacts in the resulting dose distribution. After irradiation, PET scans were performed to verify accurate dose application. Acute AV blocks were identified. No other acute effects were observed. Hearts were kept in sinus rhythm for up to 6 h in the Langendorff setup. We demonstrated that 12C ions can be used to select a small target in the heart and, thereby, influence the electrical conduction system. Second, our pilot study seems to suggest that no adverse effects have to be expected immediately during heavy ion irradiation in performing subsequent experiments with doses of 30-60 Gy and intact pigs.
Sprache:eng
Bibliogr. Hinweis:Erscheint auch als : Online-Ausgabe: Treatment of arrhythmias by external charged particle beams. - 2015
K10plus-PPN:88282161X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68389393   QR-Code
zum Seitenanfang