Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Grambow, Eberhard [VerfasserIn]  |
| Weiß, Christel [VerfasserIn]  |
Titel: | Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy |
Verf.angabe: | E. Grambow, T. Heller, P. Wieneke, C. Weiß, E. Klar, M. Weinrich |
E-Jahr: | 2018 |
Jahr: | 9 February 2018 |
Umfang: | 8 S. |
Fussnoten: | Gesehen am 14.05.2019 |
Titel Quelle: | Enthalten in: Clinical hemorheology and microcirculation |
Ort Quelle: | Amsterdam [u.a.] : IOS Press, 1997 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 68(2018), 1, Seite 17-24 |
ISSN Quelle: | 1875-8622 |
Abstract: | Background: Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. OBJECTIVE:Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. Methods: In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Results: Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Conclusions: Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound. |
DOI: | doi:10.3233/CH-170259 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.3233/CH-170259 |
| Volltext: https://content.iospress.com/articles/clinical-hemorheology-and-microcirculation/ch170259 |
| DOI: https://doi.org/10.3233/CH-170259 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1665452129 |
Verknüpfungen: | → Zeitschrift |
Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy / Grambow, Eberhard [VerfasserIn]; 9 February 2018 (Online-Ressource)
68389668