Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Emmerich, Julian [VerfasserIn]   i
 Flassbeck, Sebastian [VerfasserIn]   i
 Schmidt, Simon [VerfasserIn]   i
 Bachert, Peter [VerfasserIn]   i
 Ladd, Mark E. [VerfasserIn]   i
Titel:Rapid and accurate dictionary-based T2 mapping from multi-echo turbo spin echo data at 7 Tesla
Verf.angabe:Julian Emmerich, Sebastian Flassbeck, Simon Schmidt, Peter Bachert, Mark E. Ladd, and Sina Straub
Jahr:2019
Jahr des Originals:2018
Umfang:10 S.
Fussnoten:Gesehen am 22.05.2019 ; First published: 17 October 2018
Titel Quelle:Enthalten in: Journal of magnetic resonance imaging
Ort Quelle:New York, NY : Wiley-Liss, 1991
Jahr Quelle:2019
Band/Heft Quelle:49(2019), 5, Seite 1253-1262
ISSN Quelle:1522-2586
Abstract:Background Using lower refocusing flip angles in multi-echo turbo spin echo (ME-TSE) sequences at ultra-high magnetic field leads to non-monoexponential signal decay and overestimation of T2 values due to stimulated and secondary echoes. Purpose To investigate the feasibility of a fast and accurate reconstruction of quantitative T2 values using an ME-TSE sequence with reduced refocusing flip angles at 7 Tesla, a dictionary-based reconstruction method was developed and is presented in this work. Study Type Prospective. Subjects Phantom measurements with relaxation phantom, four healthy volunteers. Field Strength/Sequence 7 Tesla MRI, multi-echo turbo spin echo (ME-TSE), spin echo (SE), and B1 mapping. Assessment Based on Bloch simulations and the extended phase graph model, signal decay curves were calculated to account for nonrectangular slice profile, B1 inhomogeneity, and reduced refocusing flip angles and stored in a dictionary. Data obtained with an ME-TSE sequence at 7 Tesla were matched to this dictionary to obtain T2 values. To compare the proposed method to reference T2 values, a spin echo sequence with different echo times was used. Statistical Tests Welch's t-test was used to compare T2 values in phantom measurements. Results T2 values obtained with the proposed ME-TSE method coincided with the T2 values from the spin echo experiment in phantom measurements (P = 0.89 for 120° flip angle, P = 0.75 for 180° flip angle). Only for very low B1 transmit fields, a slight overestimation of T2 values was observed. In vivo measurements showed lower T2 values in gray matter (55 ± 2 millisecond) and white matter (39 ± 5 millisecond) compared with literature values of 3 Tesla data. Data Conclusions The proposed dictionary-based ME-TSE approach provided accurate T2 values in short measurement time at 7 Tesla with low specific absorption rate burden due to the reduction of refocusing flip angles. Therefore, it can provide new opportunities in clinical high-field MRI to further improve radiographic diagnosis by using quantitative imaging. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1253-1262.
DOI:doi:10.1002/jmri.26516
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1002/jmri.26516
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26516
 DOI: https://doi.org/10.1002/jmri.26516
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1666088501
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68392127   QR-Code
zum Seitenanfang