Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:He, Yong-Lan [VerfasserIn]   i
 Hausmann, Daniel [VerfasserIn]   i
 Attenberger, Ulrike [VerfasserIn]   i
 Schönberg, Stefan [VerfasserIn]   i
 Riffel, Philipp [VerfasserIn]   i
Titel:Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions
Verf.angabe:Yong-Lan He, Daniel Hausmann, John N. Morelli, Ulrike I. Attenberger, Stefan O. Schoenberg, Philipp Riffel
E-Jahr:2016
Jahr:October 2016
Umfang:5 S.
Fussnoten:Gesehen am 09.07.2019 ; Available online 1 August 2016
Titel Quelle:Enthalten in: European journal of radiology
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1990
Jahr Quelle:2016
Band/Heft Quelle:85(2016), 10, Seite 1773-1777
ISSN Quelle:1872-7727
Abstract:Purpose - To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. - Materials and methods - This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years±13.4, range 23-83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra®, Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. - Results - With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p<0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p=0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or of renal lesions were observed between the two sequences (all p>0.05). - Conclusion - Image quality, distortion, and susceptibility artifacts might be improved by using z-EPI rather than c-EPI for DWI of the kidney.
DOI:doi:10.1016/j.ejrad.2016.07.022
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.ejrad.2016.07.022
 Volltext: http://www.sciencedirect.com/science/article/pii/S0720048X1630239X
 DOI: https://doi.org/10.1016/j.ejrad.2016.07.022
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Diffusion-weighted imaging
 Kidney
 Zoomed
K10plus-PPN:1668819694
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68406421   QR-Code
zum Seitenanfang