Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Eckert, Johannes A. [VerfasserIn]   i
 Jäger, Sebastian [VerfasserIn]   i
 Klotz, Matthias C. M. [VerfasserIn]   i
 Schwarze, Martin [VerfasserIn]   i
 Bitsch, Rudi G. [VerfasserIn]   i
Titel:Can intraoperative measurement of bone quality help in decision making for cementless unicompartmental knee arthroplasty?
Verf.angabe:Johannes A. Eckert, Sebastian Jaeger, Matthias C. Klotz, Martin Schwarze, Rudi G. Bitsch
E-Jahr:2018
Jahr:20 May 2018
Umfang:8 S.
Fussnoten:Gesehen am 15.07.2019
Titel Quelle:Enthalten in: The knee
Ort Quelle:Amsterdam [u.a.] : Elsevier Science, 1994
Jahr Quelle:2018
Band/Heft Quelle:25(2018), 4, Seite 609-616
ISSN Quelle:1873-5800
Abstract:Background - In uncemented total hip arthroplasty (THA), low bone mineral density (BMD) is associated with aseptic loosening. BMD is usually assessed via dual-energy X-ray absorptiometry (DXA) or quantitative computed tomography, which takes time and exposes patients to radiation. Due to its low risk profile, intraoperative measurement of the trabecular stability might be a useful alternative to DXA. - Methods - In 24 human femora, BMD was analysed using DXA at the femoral necks and the knees. Performing the standard Oxford Unicompartmental Knee Arthroplasty (OUKA) implantation procedure, a wingblade (DensiProbe) coupled to a torque probe was used to evaluate the trabecular peak torque. The standard procedure was modified: before the completion of the central peg drill hole, the DensiProbe was inserted into the pre-drilled hole and then turned until a loss of resistance was achieved. The obtained data was then correlated with BMD at the femoral neck as well as the knee. - Results - In all tested regions, a higher peak torque was observed in correlation with a higher BMD. - Conclusions - As demonstrated, the DensiProbe can be a helpful tool to assess the bone quality intraoperatively in OUKA. It can be a valuable decision guidance when faced with choosing between a cemented and a cementless implant. Due to the fact that the central peg hole of the OUKA can be used for the procedure, no additional risk for the patient exists, while the additional work for the surgeon is minimal.
DOI:doi:10.1016/j.knee.2018.03.013
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1016/j.knee.2018.03.013
 Volltext: http://www.sciencedirect.com/science/article/pii/S0968016018301376
 DOI: https://doi.org/10.1016/j.knee.2018.03.013
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:BMD
 DensiProbe
 Oxford unicompartmental
 Torque resistance
 Trabecular stability
K10plus-PPN:166913203X
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68408530   QR-Code
zum Seitenanfang