| Online-Ressource |
Verfasst von: | Hardiansyah, Deni [VerfasserIn]  |
| Glatting, Gerhard [VerfasserIn]  |
Titel: | Sensitivity analysis of a physiologically based pharmacokinetic model used for treatment planning in peptide receptor radionuclide therapy |
Verf.angabe: | Deni Hardiansyah, Nusrat Jihan Begum, Peter Kletting, Felix M. Mottaghy, Gerhard Glatting |
E-Jahr: | 2016 |
Jahr: | July 12, 2016 |
Umfang: | 8 S. |
Fussnoten: | Gesehen am 18.07.2019 |
Titel Quelle: | Enthalten in: Cancer biotherapy and radiopharmaceuticals |
Ort Quelle: | Larchmont, NY : Liebert, 1996 |
Jahr Quelle: | 2016 |
Band/Heft Quelle: | 31(2016), 6, Seite 217-224 |
ISSN Quelle: | 1557-8852 |
Abstract: | The aim of this work was to evaluate the sensitivity of time-integrated activity coefficients (TIACs) on the erroneously chosen prior knowledge in a physiologically based pharmacokinetic (PBPK) model used for treatment planning in peptide receptor radionuclide therapy (PRRT). Parameters of the PBPK model were fitted to the biokinetic data of 15 patients after the injection of 111In-DTPAOC. The fittings were performed using fixed parameter values taken from literature as prior knowledge (reference case, Ref). The fixed parameters were gender, physical information (e.g., body weight), dissociation rate koff, dissociation constant KD, fraction of blood flow, and spleen and liver volumes. The fittings were repeated with changed fixed parameters (Changed). The relative deviations (RDs) of TIACs calculated from Changed and Ref were analyzed for kidneys, tumor, liver, spleen, remainder, whole body, and serum. A changed koff has the largest effect on RD, the largest RD values were found for changed koff = 0.001 L/min: RDkidneys = (3 ± 3)%, RDtumor = (0.5 ± 4)%, RDliver = (6 ± 9)%, RDspleen = (5 ± 5)%, RDremainder = (2 ± 31)%, RDserum = (-4 ± 25)%, and RDwholebody = (3 ± 16)%. For other changed parameters, the maximum RDs were <1%. The calculation of organ TIACs in PRRT using the PBPK model was little affected by assigning wrong prior knowledge to the evaluated patients. The calculation of bone marrow-absorbed doses could be affected by the inaccurate TIACs of serum and remainder in the case of an inadequate koff. |
DOI: | doi:10.1089/cbr.2016.2012 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1089/cbr.2016.2012 |
| Volltext: https://www.liebertpub.com/doi/10.1089/cbr.2016.2012 |
| DOI: https://doi.org/10.1089/cbr.2016.2012 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1669418774 |
Verknüpfungen: | → Zeitschrift |
Sensitivity analysis of a physiologically based pharmacokinetic model used for treatment planning in peptide receptor radionuclide therapy / Hardiansyah, Deni [VerfasserIn]; July 12, 2016 (Online-Ressource)