Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Häfner, Matthias [VerfasserIn]   i
 Verma, Vivek [VerfasserIn]   i
 Bougatf, Nina [VerfasserIn]   i
 Mielke, Thomas [VerfasserIn]   i
 Tonndorf-Martini, Eric [VerfasserIn]   i
 König, Laila [VerfasserIn]   i
 Uhlmann, Lorenz [VerfasserIn]   i
 Eichhorn, Florian [VerfasserIn]   i
 Winter, Hauke [VerfasserIn]   i
 Grosch, Heidrun [VerfasserIn]   i
 Haberer, Thomas [VerfasserIn]   i
 Herfarth, Klaus [VerfasserIn]   i
 Debus, Jürgen [VerfasserIn]   i
 Rieken, Stefan [VerfasserIn]   i
Titel:Dosimetric comparison of advanced radiotherapy approaches using photon techniques and particle therapy in the postoperative management of thymoma
Verf.angabe:Matthias Felix Haefner, Vivek Verma, Nina Bougatf, Thomas Mielke, Eric Tonndorf-Martini, Laila König, Jean-Claude M. Rwigema, Charles B. Simone 2nd, Lorenz Uhlmann, Florian Eichhorn, Hauke Winter, Heidrun Grosch, Thomas Haberer, Klaus Herfarth, Jürgen Debus and Stefan Rieken
E-Jahr:2018
Jahr:28 Sep 2018
Umfang:8 S.
Fussnoten:Gesehen am 19.08.2019
Titel Quelle:Enthalten in: Acta oncologica
Ort Quelle:Abingdon : Taylor & Francis Group, 1987
Jahr Quelle:2018
Band/Heft Quelle:57(2018), 12, Seite 1713-1720
ISSN Quelle:1651-226X
Abstract:Background: The purpose of this study was to compare dosimetric differences related to target volume and organs-at-risk (OAR) using 3D-conformal radiotherapy (3DCRT), volumetric modulated arc therapy (VMAT), TomoTherapy (Tomo), proton radiotherapy (PRT), and carbon ion radiotherapy (CIRT) as part of postoperative thymoma irradiation.Material and methods: This single-institutional analysis included 10 consecutive patients treated with adjuvant radiotherapy between December 2013 and September 2016. CT-datasets and respective RT-structures were anonymized and plans for all investigated RT modalities (3DCRT, VMAT, Tomo, PRT, CIRT) were optimized for a total dose of 50 Gy in 25 fractions. Comparisons between target volume and OAR dosimetric parameters were performed using the Wilcoxon rank-sum test.Results: The best target volume coverage (mean PTV V95% for all patients) was observed for Tomo (97.9%), PRT (97.6%), and CIRT (96.6%) followed by VMAT (85.4%) and 3DCRT (74.7%). PRT and CIRT both significantly reduced mean doses to the lungs, breasts, heart, and esophagus, as well as the spinal cord maximum dose compared with photon modalities. Among photon-based techniques, VMAT showed improved OAR sparing over 3DCRT. Tomo was associated with considerable low-dose exposure to the lungs, breasts, and heart.Conclusions: Particle radiotherapy (PRT, CIRT) showed superior OAR sparing and optimal target volume coverage. The observed dosimetric advantages are expected to reduce toxicity rates. However, their clinical impact must be investigated prospectively.
DOI:doi:10.1080/0284186X.2018.1502467
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://www.tandfonline.com/doi/pdf/10.1080/0284186X.2018.1502467?needAccess=true
 Volltext: https://doi.org/10.1080/0284186X.2018.1502467
 DOI: https://doi.org/10.1080/0284186X.2018.1502467
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1671589505
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68421925   QR-Code
zum Seitenanfang