Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Guerin, Bastien [VerfasserIn]   i
 Davids, Mathias [VerfasserIn]   i
Titel:The "virtual DBS population"
Titelzusatz:five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies
Verf.angabe:Bastien Guerin, Maria Ida Iacono, Mathias Davids, Darin Dougherty, Leonardo M. Angelone and Lawrence L. Wald
E-Jahr:2019
Jahr:4 February 2019
Umfang:14 S.
Fussnoten:Gesehen am 24.10.2019
Titel Quelle:Enthalten in: Physics in medicine and biology
Ort Quelle:Bristol : IOP Publ., 1956
Jahr Quelle:2019
Band/Heft Quelle:64(2019,3) Artikel-Nummer 035021, 14 Seiten
ISSN Quelle:1361-6560
Abstract:We design, develop, and disseminate a ‘virtual population’ of five realistic computational models of deep brain stimulation (DBS) patients for electromagnetic (EM) analysis. We found five DBS patients in our institution’ research patient database who received high quality post-DBS surgery computer tomography (CT) examinations of the head and neck. Three patients have a single implanted pulse generator (IPG) and the two others have two IPGs (one for each lead). Moreover, one patient has two abandoned leads on each side of the head. For each patient, we combined the head and neck volumes into a ‘virtual CT’, from which we extracted the full-length DBS path including the IPG, extension cables, and leads. We corrected topology errors in this path, such as self-intersections, using a previously published optimization procedure. We segmented the virtual CT volume into bones, internal air, and soft tissue classes and created two-manifold, watertight surface meshes of these distributions. In addition, we added a segmented model of the brain (grey matter, white matter, eyes and cerebrospinal fluid) to one of the model (nickname Freddie) that was derived from a T1-weighted MR image obtained prior to the DBS implantation. We simulated the EM fields and specific absorption rate (SAR) induced at 3 Tesla by a quadrature birdcage body coil in each of the five patient models using a co-simulation strategy. We found that inter-subject peak SAR variability across models was independent of the target averaging mass and equal to 45%. In our simulations of the full brain segmentation and six simplified versions of the Freddie model, the error associated with incorrect dielectric property assignment around the DBS electrodes was greater than the error associated with modeling the whole model as a single tissue class. Our DBS patient models are freely available on our lab website (Webpage of the Martinos Center Phantom Resource 2018 https://phantoms.martinos.org/Main_Page).
DOI:doi:10.1088/1361-6560/aafce8
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1088/1361-6560/aafce8
 Verlag: https://iopscience.iop.org/article/10.1088/1361-6560/aafce8
 DOI: https://doi.org/10.1088/1361-6560/aafce8
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1678145424
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68435328   QR-Code
zum Seitenanfang