Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Son, Hyeck Soo [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
 Yildirim, Timur Mert [VerfasserIn]   i
 Baur, Isabella [VerfasserIn]   i
 Łabuz, Grzegorz [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
Titel:Functional outcomes and reading performance after combined implantation of a amall-aperture lens and a segmental refractive bifocal lens
Verf.angabe:Hyeck Soo Son, Ramin Khoramnia, Timur M. Yildirim, Isabella Baur, Grzegorz Labuz, Gerd U. Auffarth
E-Jahr:2019
Jahr:September 10, 2019
Umfang:8 S.
Fussnoten:Gesehen am 08.10.2019
Titel Quelle:Enthalten in: Journal of refractive surgery
Ort Quelle:Thorofare, NJ : SLACK Inc., 1996
Jahr Quelle:2019
Band/Heft Quelle:35(2019), 9, Seite 551-558
ISSN Quelle:1938-2391
Abstract:Purpose: Clinical evaluation of the visual outcomes after implantation of a small-aperture extended depth of focus (EDOF) intraocular lens (IOL) and a segmental refractive bifocal lens. Methods: In this prospective study, 13 patients with cataract received a small-aperture IC-8 IOL (AcuFocus, Irvine, CA) in one eye and a segmental-refractive Lentis Mplus LS-313 MF20 IOL (Oculentis, Berlin, Germany) in the fellow eye. The clinical examination included measurements of uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity. Additionally, a defocus curve was obtained from +2.00 to −5.00 diopters (D) and a Salzburg Reading Desk was used to assess the patients' reading acuity at intermediate and near distances. A halo and glare simulator was used to evaluate the postoperative perception of dysphotopsia. Results: At 5 months postoperatively, the mean binocular visual results demonstrated UDVA, UIVA, and UNVA values of −0.04 ± 0.11, 0.00 ± 0.10, and 0.11 ± 0.08 logMAR, respectively. The binocular distance-corrected reading performance test also confirmed the improved visual function, with an intermediate reading acuity of 0.12 logMAR at 69.21 cm and a near reading acuity of 0.19 logMAR at 41.63 cm. The mean halo size was 32.54 ± 22.38, mean halo intensity was 34.46 ± 21.95, mean glare size was 9.00 ± 17.47, and mean glare intensity was 9.92 ± 16.84. Conclusions: The new concept of a combined implantation of a small-aperture IOL and a segmental-refractive bifocal lens showed good results in far and intermediate distances and functional results at near distance, while causing minimal photic phenomena.
DOI:doi:10.3928/1081597X-20190806-02
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.3928/1081597X-20190806-02
 Verlag: https://www.healio.com/ophthalmology/journals/jrs/2019-9-35-9/{3e171b23-6c5d-46fd-a0ef-c74346a5bcde}/functional-outcomes-and-reading-performance-after-combined-implantation-of-a-small-aperture-lens-and-a-segmental-refractive-bifocal-lens
 DOI: https://doi.org/10.3928/1081597X-20190806-02
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1678468002
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68436278   QR-Code
zum Seitenanfang