Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Maur, Susanne [VerfasserIn]  |
| Stsepankou, Dzmitry [VerfasserIn]  |
| Hesser, Jürgen [VerfasserIn]  |
Titel: | Auto-calibration by locally consistent contours for dental CBCT |
Verf.angabe: | S. Maur, D. Stsepankou, J. Hesser |
E-Jahr: | 2018 |
Jahr: | 29 October 2018 |
Umfang: | 12 S. |
Fussnoten: | Gesehen am 18.10.2019 |
Titel Quelle: | Enthalten in: Physics in medicine and biology |
Ort Quelle: | Bristol : IOP Publ., 1956 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 63 (2018,21) Artikel-Nummer 215018, Seite 1-12, 12 Seiten |
ISSN Quelle: | 1361-6560 |
Abstract: | The image quality of dental cone-beam computed tomography (CBCT) is limited by the accuracy of device calibration. Inaccurate calibration introduces errors in the reconstruction process, which may lead to severe artifacts in the reconstructed volume. Patient motion during scan acquisition induces similar effects. This paper introduces a novel auto-calibration approach calculating geometrical projection parameters from unknown patient geometry. We formulate consistency conditions linking the information of consecutive projection images and a regularization technique to prevent overall distortions. Implemented as a global optimization problem we present an efficient greedy optimizer as well. Our strategy turns out to be robust towards inaccurate initialization. As our method does not rely on consistency between projection data and tomography reconstruction it is robust towards reconstruction artifacts such as e.g. truncation. Applying our approach for auto-calibration shows a relative improvement of sharpness up to of in a standard dental CBCT setup. Evaluation is performed on digital reconstructed radiographs (DRRs) of a CT head-scan. In particular different motion types are considered and the number of anatomical structures used for calibration is varied to achieve an understanding of the behavior of the approach. |
DOI: | doi:10.1088/1361-6560/aae66d |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1088/1361-6560/aae66d |
| DOI: https://doi.org/10.1088/1361-6560/aae66d |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 167912255X |
Verknüpfungen: | → Zeitschrift |
Auto-calibration by locally consistent contours for dental CBCT / Maur, Susanne [VerfasserIn]; 29 October 2018 (Online-Ressource)
68442044