| Online-Ressource |
Verfasst von: | Khoramnia, Ramin [VerfasserIn]  |
| Yildirim, Timur Mert [VerfasserIn]  |
| Tandogan, Tamer [VerfasserIn]  |
| Liebing, Stephanie [VerfasserIn]  |
| Łabuz, Grzegorz [VerfasserIn]  |
| Choi, Chul Y. [VerfasserIn]  |
| Auffarth, Gerd U. [VerfasserIn]  |
Titel: | Optische Qualität dreier trifokaler Intraokularlinsenmodelle |
Verf.angabe: | R. Khoramnia, T.M. Yildirim, T. Tandogan, S. Liebing, G. Łabuz, C.Y. Choi, G. Auffarth |
E-Jahr: | 2018 |
Jahr: | 27. September 2017 |
Umfang: | 8 S. |
Fussnoten: | Gesehen am 24.10.2019 |
Titel Quelle: | Enthalten in: Der Ophthalmologe |
Ort Quelle: | Berlin : Springer, 1996 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 115(2018), 1, Seite 21-28 |
ISSN Quelle: | 1433-0423 |
Abstract: | BackgroundKnowledge of the optical quality of different trifocal intraocular lenses (IOL) is important in customized patient care.ObjectiveDifferent trifocal IOL were compared regarding their optical quality.Materials and methodsWe analyzed the FineVision (PhysIOL, Liège, Belgium), the AT LISA tri 839MP (Zeiss, Oberkochen, Germany), and the AcrySofIQ PanOptix (Alcon, Fort Worth, TX, USA) with a power of +21D for the distance using the OptiSpheric IOL PRO optical bench (Trioptics, Wedel, Germany). The additions for the near and intermediate distances were as follows: +3.5D/+1.75D (FineVision), +3.33D/+1.66D (AT LISA tri), and + 3,25D/+ 2,17D (PanOptix). We evaluated the modulation transfer function (MTF) at a spatial frequency of 50lp/mm and the Strehl ratio using 3‑ (photopic) and 4.5-mm (mesopic) apertures.ResultsThe MTF at 50 lp/mm (FineVision/AT Lisa tri/PanOptix) at the far focus was 0.373/0.399/0.400 (3-mm aperture) and 0.512/0.311/0.243 (4.5-mm aperture). At the intermediate focus, the MTF was 0.162/0.147/0.153 (3-mm aperture) and 0.092/0.125/0.137 (4.5-mm aperture). The MTF at the near focus was 0.229/0.192/0.404 (3-mm aperture) and 0.217/0.212/0.169 (4.5-mm aperture). The Strehl ratio was 0.335/0.298/0.370 (3-mm aperture) and 0.243/0.180/0.270 (4.5-mm aperture) at the far focus. At intermediate distances, the Strehl ratio was 0.189/0.185/0.162 (3-mm aperture) and 0.099/0.097/0.114 (4.5-mm aperture). The Strehl ratio was 0.305/0.283/0.464 (3-mm aperture) and 0.177/0.181/0.155 (4.5-mm aperture) at the near focus.ConclusionEvaluation of the three trifocal IOL models at the optical bench could show distinct peaks at the far, intermediate, and near focus. The results were comparable in terms of optical performance. |
DOI: | doi:10.1007/s00347-017-0573-0 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1007/s00347-017-0573-0 |
| DOI: https://doi.org/10.1007/s00347-017-0573-0 |
Datenträger: | Online-Ressource |
Sprache: | ger |
Sach-SW: | Cataract extraction |
| Kataraktoperation |
| Lenses |
| Linsen |
| Optical devices |
| Optische Geräte |
| Pseudophakia |
| Pseudophakie |
| Sehschärfe |
| Visual acuity |
K10plus-PPN: | 1679743813 |
Verknüpfungen: | → Zeitschrift |
Optische Qualität dreier trifokaler Intraokularlinsenmodelle / Khoramnia, Ramin [VerfasserIn]; 27. September 2017 (Online-Ressource)