Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Schall, Florian [VerfasserIn]   i
 Wolf, Sebastian Immanuel [VerfasserIn]   i
Titel:German Society of Biomechanics (DGfB) Young Investigator Award 2019
Titelzusatz:Proof-of-concept of a novel knee joint simulator allowing rapid motions at physiological muscle and ground reaction forces
Verf.angabe:Florian Schall, Andreas M. Seitz, Steffen Hacker, Stefan van Drongelen, Sebastian I. Wolf, Anita Ignatius and Lutz Dürselen
E-Jahr:2019
Jahr:27 September 2019
Umfang:10 S.
Fussnoten:Gesehen am 29.10.2019
Titel Quelle:Enthalten in: Frontiers in Bioengineering and Biotechnology
Ort Quelle:Lausanne : Frontiers Media, 2013
Jahr Quelle:2019
Band/Heft Quelle:7(2019) Artikel-Nummer 244, 10 Seiten
ISSN Quelle:2296-4185
Abstract:The in vitro determination of realistic loads acting in knee ligaments, articular cartilage, menisci and their attachments during daily activities require the creation of physiological muscle forces, ground reaction force and unconstrained kinematics. However, no in vitro test setup is currently available that is able to simulate such physiological loads during squatting and jump landing exercises. Therefore, a novel knee joint simulator allowing such physiological loads in combination with realistic, rapid movements is presented. To gain realistic joint positions and muscle forces serving as input parameters for the simulator, a combined in vivo motion analysis and inverse dynamics (MAID) study was undertaken with 11 volunteers performing squatting and jump landing exercises. Subsequently, an in vitro study using nine human knee joint specimens was conducted to prove the functionality of the simulator. To do so, slow squatting without muscle force simulation representing quasi-static loading conditions and slow squatting and jump landing with physiological muscle force simulation were carried out. During all tests ground reaction force, tibiofemoral contact pressure and tibial rotation characteristics were simultaneously recorded. The simulated muscle forces obtained were in good correlation (0.48  R  0.92) with those from the in vivo MAID study. The resulting vertical ground reaction force showed a correlation of R= 0.93. On the basis of the target parameters of ground reaction force, tibiofemoral contact pressure and tibial rotation, it could be concluded that the knee joint load was loaded physiologically. Therefore, this is the first in vitro knee joint simulator allowing squatting and jump landing exercises in combination with physiological muscle forces that finally result in realistic ground reaction forces and physiological joint loading conditions.
DOI:doi:10.3389/fbioe.2019.00244
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.3389/fbioe.2019.00244
 Verlag: https://www.frontiersin.org/articles/10.3389/fbioe.2019.00244/full
 DOI: https://doi.org/10.3389/fbioe.2019.00244
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Biomechanics
 Contact pressure
 in vitro
 Knee
 muscle forces
 Rapid movement
 simulator
K10plus-PPN:1680637258
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68447753   QR-Code
zum Seitenanfang