Status: Bibliographieeintrag
Standort: ---
Exemplare:
---
| Online-Ressource |
Verfasst von: | Łabuz, Grzegorz [VerfasserIn]  |
| Yildirim, Timur Mert [VerfasserIn]  |
| Khoramnia, Ramin [VerfasserIn]  |
| Auffarth, Gerd U. [VerfasserIn]  |
Titel: | Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas |
Verf.angabe: | Grzegorz Łabuz, Timur M. Yildirim, Thomas J.T.P. van den Berg, Ramin Khoramnia, Gerd U. Auffarth |
E-Jahr: | 2018 |
Jahr: | 15 June 2018 |
Umfang: | 8 S. |
Fussnoten: | Gesehen am 04.11.2019 |
Titel Quelle: | Enthalten in: Journal of cataract and refractive surgery |
Ort Quelle: | Fairfax, Va. : Soc., 1986 |
Jahr Quelle: | 2018 |
Band/Heft Quelle: | 44(2018), 5, Seite 615-622 |
ISSN Quelle: | 1873-4502 |
Abstract: | Purpose - To assess the optical quality of intraocular lenses (IOLs) explanted because of opacification after the intraocular injection of gas. - Setting - David J. Apple Laboratory, Heidelberg, Germany. - Design - Experimental study. - Methods - Four hydrophilic acrylic IOLs were studied, each with a centrally localized round opacification pattern associated with the intraocular use of gas. Laboratory analysis included gross examination with a light microscope, followed by alizarin and von Kossa staining. Optical quality was assessed by examining the modulation transfer function (MTF) and straylight. Results were compared with those of a control IOL and normative data for straylight of the crystalline lens. The following parameters were derived from image analysis: opacified surface fraction, light loss in the opacified surface, and the area and number of granules. The relationship between straylight increase and those parameters was studied. - Results - Fine granules were identified on the IOL surface and subsurface. The granules stained positive for calcium, and the MTF levels of 2 IOLs dropped markedly. The other 2 showed relatively minor changes. The straylight was extremely increased in 3 IOLs up to (and above) a level of that of a cataractous lens. A proportional relationship was found between straylight and the morphological parameters from image analysis. - Conclusions - Intraocular lenses with centrally localized opacification have a strong potential for deteriorating optical performance. However, the optical quality might differ depending on the morphology of opacification. A serious straylight increase was found in most of these IOLs, suggesting that affected patients may suffer from glare-related symptoms. |
DOI: | doi:10.1016/j.jcrs.2018.01.033 |
URL: | Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.
Volltext: https://doi.org/10.1016/j.jcrs.2018.01.033 |
| Verlag: http://www.sciencedirect.com/science/article/pii/S0886335018302906 |
| DOI: https://doi.org/10.1016/j.jcrs.2018.01.033 |
Datenträger: | Online-Ressource |
Sprache: | eng |
K10plus-PPN: | 1681170477 |
Verknüpfungen: | → Zeitschrift |
Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas / Łabuz, Grzegorz [VerfasserIn]; 15 June 2018 (Online-Ressource)
68451026