Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Künzel, Luise [VerfasserIn]   i
 Dohm, Oliver Steffen [VerfasserIn]   i
 Alber, Markus [VerfasserIn]   i
 Zips, Daniel [VerfasserIn]   i
 Thorwarth, Daniela [VerfasserIn]   i
Titel:Automatic replanning of VMAT plans for different treatment machines
Titelzusatz:a template-based approach using constrained optimization
Verf.angabe:Luise A. Künzel, Oliver S. Dohm, Markus Alber, Daniel Zips, Daniela Thorwarth
E-Jahr:2018
Jahr:30 May 2018
Umfang:8 S.
Fussnoten:Gesehen am 14.11.2019
Titel Quelle:Enthalten in: Strahlentherapie und Onkologie
Ort Quelle:Berlin : Springer Medizin, 1997
Jahr Quelle:2018
Band/Heft Quelle:194(2018), 10, Seite 921-928
ISSN Quelle:1439-099X
Abstract:PurposeTo investigate a new automatic template-based replanning approach combined with constrained optimization, which may be highly useful for a rapid plan transfer for planned or unplanned machine breakdowns. This approach was tested for prostate cancer (PC) and head-and-neck cancer (HNC) cases.MethodsThe constraints of a previously optimized volumetric modulated arc therapy (VMAT) plan were used as a template for automatic plan reoptimization for different accelerator head models. All plans were generated using the treatment planning system (TPS) Hyperion. Automatic replanning was performed for 16 PC cases, initially planned for MLC1 (4 mm MLC) and reoptimized for MLC2 (5 mm) and MLC3 (10 mm) and for 19 HNC cases, replanned from MLC2 to MLC3. EUD, Dmean, D2%, and D98% were evaluated for targets; for OARs EUD and D2% were analyzed. Replanning was considered successful if both plans fulfilled equal constraints.ResultsAll prostate cases were successfully replanned. The mean relative target EUD deviation was −0.15% and −0.57% for replanning to MLC2 and MLC3, respectively. OAR sparing was successful in all cases. Replanning of HNC cases from MLC2 to MLC3 was successful in 16/19 patients with a mean decrease of −0.64% in PTV60 EUD. In three cases target doses were substantially decreased by up to −2.58% (PTV60) and −3.44% (PTV54), respectively. Nevertheless, OAR sparing was always achieved as planned.ConclusionsAutomatic replanning of VMAT plans for a different treatment machine by using pre-existing constraints as a template for a reoptimization is feasible and successful in terms of equal constraints.
DOI:doi:10.1007/s00066-018-1319-x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1007/s00066-018-1319-x
 DOI: https://doi.org/10.1007/s00066-018-1319-x
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Automatic re-planning
 Automatische Umplanung
 Beschränkte Optimierung
 Constrained optimization
 Geräteausfallkonzept
 Machine failure concept
 Radiotherapy
 Strahlentherapie
 Volumenmodulierte Rotationsbestrahlung
 Volumetric modulated arc therapy
K10plus-PPN:1681870460
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68455185   QR-Code
zum Seitenanfang